Service 26 (Drain Valve)
Micro switch ball valve in permanent closed position.
Unit out of order
Indication Service 26
Activate ball valve in the function
test.
NO
YES
Output voltage at I/O
pcb X25 7/8 (12V DC)
present?
Change I/O pcb
Check motor ball valve, micro
switch, cable, connector. Complete
ball valve unit must be changed.
NO
Service 27 (Drain Valve)
Micro switch ball valve in permanent open position.
CleanJet can not be used
Indication Service 27
Separate unit from mains (swit-
ching off and on with main switch
is not enough). After approx. 5
seconds connect unit to mains .
YES
YES
Is Service 27 deleted?
Start a CleanJet-program and
check for correct function
Change I/O pcb
NO
Output voltage at I/O
pcb X25 7/8 (12V DC)
present?
Ball valve blocked by dirt.
Motor of ball valve, micro switch,
cable and/or connector defective.
Change unit if necessary
Activate ball valve with the func-
tion test
NO
Should Service 27 appear more often and I/O-pcb with revision status 402 respec. 403 is installed,
change I/O-
pcb
Summary of Contents for Combi Master
Page 1: ...Edition 10 2008a 1 Training Manual SCC Line SelfCooking Center Combi Master...
Page 2: ...2 Edition 10 2008a...
Page 34: ...34 CM Edition 10 2008...
Page 35: ...35 SCC Edition 10 2008a SCC Control panel...
Page 47: ...47 SCC Edition 10 2008a Parts identi cation CareControl 1 2 3 3 4 4 11 1 2 3 4 11 4 2 3 1 2 11...
Page 58: ...58 SCC Edition 10 2008a...
Page 66: ...66 SCC Edition 10 2008a...
Page 100: ...100 SCC Edition 10 2008a...
Page 126: ...126 Gas Edition 10 2008a...
Page 139: ...Edition 10 2008a 139 UltraVent...
Page 153: ...153 Common Information Edition 10 2008a...
Page 166: ...166 Trouble shooting SCC Edition 10 2008a...
Page 177: ...177 SCC Edition 10 2008a...