56
SCC
Edition 10-2008a
Fan motor SCC 40.00.274
Jumper 40.01.581 is used on oor model 201 and 202 for top position motor only!
Jumper is not used on models 61 - 102 with one motor only!
(Service 34 will be shown when jumper is set wrongly)
LED code fan motor SCC and CM from 04/2004
Reason
Remedy
1x
Motor doesn’t start, no changing
signal from hallsensor
Check for motor blockage or change motor.
2x
Voltage too low on motor pcb
Check supply voltage or
change motor.
3x
Voltage too high on motor pcb
Check supply voltage or
change motor.
4x
rpm measurement defective
Change motor.
5x
Motor pcb temperature >105°C
Check cooling system (cooling fan, air
intake lter), otherwise change motor
6x
Supply voltage <80V
Check power supply
(F1-F2)
7x
Motor pcb defective
Change motor.
8x
Motor pcb defective
Change motor.
Fan motor SCC 40.00.276 for units 3AC 400-480V (without neutral)
LED
Jumper
Summary of Contents for Combi Master
Page 1: ...Edition 10 2008a 1 Training Manual SCC Line SelfCooking Center Combi Master...
Page 2: ...2 Edition 10 2008a...
Page 34: ...34 CM Edition 10 2008...
Page 35: ...35 SCC Edition 10 2008a SCC Control panel...
Page 47: ...47 SCC Edition 10 2008a Parts identi cation CareControl 1 2 3 3 4 4 11 1 2 3 4 11 4 2 3 1 2 11...
Page 58: ...58 SCC Edition 10 2008a...
Page 66: ...66 SCC Edition 10 2008a...
Page 100: ...100 SCC Edition 10 2008a...
Page 126: ...126 Gas Edition 10 2008a...
Page 139: ...Edition 10 2008a 139 UltraVent...
Page 153: ...153 Common Information Edition 10 2008a...
Page 166: ...166 Trouble shooting SCC Edition 10 2008a...
Page 177: ...177 SCC Edition 10 2008a...