18
CM
Edition 10-2008
Function Step
Responsible sensor
1. Select Combi mode
Set temperature 30-300°C (86-572°F)
2. Select time or core temperature
3. Close cabinet door
Reed switch S3
4. Check water level inside steam generator
Level electrode S2 inside Steam Generatorr
5. Time based preheating of steam generator,
Thermocouple B5 inside Steam Generator
if B5 is below 85°C (185°F);
6. Timer starts after successful preheating
Logic on PCB
(blinking dot in Display)
7. Hot Air supply until set temperature
Cabinet sensor B1
inside
cabinet.
Hot air has priority
8. Steam supply up to steam saturation
Quenching sensor B2
inside cabinet
(Steam Control)
9. Quenching (set to 70°C/158°F)
Quenching sensor B2
Note: Reduction of fan motor speed
In case the actual
temperature
in the range
of 30-99°C
(86 - 210°F) is 2°C / 4°F higher
than the set temperature for longer than 2 minutes, the fan speed will be reduced automati-
cally.
CM - Sequence of events
Mode: Combination
; Temp. range 30-300°C (86-572°F)
B1
B3
F4
M4
Y1
Y2
B2
M1
S2
B5
F3
S3
Summary of Contents for Combi Master
Page 1: ...Edition 10 2008a 1 Training Manual SCC Line SelfCooking Center Combi Master...
Page 2: ...2 Edition 10 2008a...
Page 34: ...34 CM Edition 10 2008...
Page 35: ...35 SCC Edition 10 2008a SCC Control panel...
Page 47: ...47 SCC Edition 10 2008a Parts identi cation CareControl 1 2 3 3 4 4 11 1 2 3 4 11 4 2 3 1 2 11...
Page 58: ...58 SCC Edition 10 2008a...
Page 66: ...66 SCC Edition 10 2008a...
Page 100: ...100 SCC Edition 10 2008a...
Page 126: ...126 Gas Edition 10 2008a...
Page 139: ...Edition 10 2008a 139 UltraVent...
Page 153: ...153 Common Information Edition 10 2008a...
Page 166: ...166 Trouble shooting SCC Edition 10 2008a...
Page 177: ...177 SCC Edition 10 2008a...