Common Issues
The following problems are not a malfunction and in most situations will not require repairs.
Troubleshooting
SAFETY PRECAUTIONS
If ANY of the following conditions occurs, turn off your unit immediately!
The power cord is damaged or abnormally warm
You smell a burning odor
The unit emits loud or abnormal sounds
A power fuse blows or the circuit breaker frequently trips
Water or other objects fall into or out of the unit
•
•
•
•
•
Issue
Possible Causes
Air conditioner
does not start
The air conditioner is unplugged.
The air filter is dirty.
Airflow is restricted .
The fuse is blown/circuit breaker is tripped.
Power failure.
Cool efficiency
is not good
Air conditioner
freezing up
DO NOT ATTEMPT TO FIX THESE YOURSELF! CONTACT
SHUN HING ELECTRIC SERVICE
CENTRE LTD
.
IMMEDIATELY!
18
What To Do
- Make sure the air conditioner plug is pushed
completely into the outlet and switched on.
- Check the house fuse/circuit breaker box
and replace the fuse or reset the breaker.
- If power failure occurs, switch off and disconnect/
unplug the power cord. When power is restored,
reconnect (plug in) the power cord, switch on the
power and wait 3 minutes to restart the air
conditioner to prevent tripping of the compressor
overload.
- Make sure there are no curtains, blinds, or furniture
blocking the front of the air conditioner.
- Clean the filter at least every 2 weeks.
- See the operating instructions section.
- When the air conditioner is first turned on you
need to allow time for the room to cool down.
The room may have been hot.
Cold air is escaping.
- Check if doors and windows are opened.
- Set the air conditioner's vent to the closed position.
Cooling coils have iced up.
- See Air Conditioner Freezing Up below.
Ice blocks the air flow and stops the air
conditioner from cooling the room.
- Set the fan at MED or HIGH until the ice melts.
Summary of Contents for RC-S70U
Page 1: ...RC S70U RC S90U RC S120U RC S180U RC S240U...
Page 2: ...Precautions 1 3 4 5 6 7 8 9 10 11 12 13 R32 IEC 60335 2 40 14 0 75 2...
Page 3: ...1 2 3 4 5...
Page 4: ...03 09 10 12 12 13 15 16 2018 12 31...
Page 5: ...3 R32...
Page 6: ...4 3 10mA RCD 30mA 1 2 3 4 5 6 7 1 3 8 9 10 11 PCB 220V...
Page 7: ...5 R32 R32 R32 IEC 60335 2 40 2018 R32...
Page 8: ...6 1 2 3 4 5 6 1 2 3 4 5 6 7 8 9 R32...
Page 9: ...7 7 1 2 8 9 10 11 LFL 25 OFN 12 OFN OFN OFN 13 OFN...
Page 10: ...8 14 a b c d e f g h 80 i j k 15 16...
Page 13: ...11...
Page 14: ...12 A B 1 2 3 4 50 C 122 F 1 2 A B 3 40 C 104 F 4 5 6 90...
Page 15: ...1 3 4 2 3 3 4...
Page 16: ...6 10 11 5 5 6 7 14 8 9 1 5 2 6 1 2 A B 5 7 3 7 1 8 2 3 7 1 9 2 10 8 1 2 2 11 3 4 4...
Page 17: ...15 a b c d e f 1 a b 2 PVC c 3 d e RC S180U RC S240U 4 6 7 3 2 MED HIGH...
Page 18: ...RC S70U RC S90U 450 6x350x675 RC S120U RC S180U 660x428x780 RC S240U 16...
Page 19: ...1 0 2 0 0 3 28612767 0 0 2406 5666 o o 0...
Page 43: ......