F3: Exhaust temperature sensor error;

F4: Outdoor electric EE error;

P0: IPM module error;

P1: Voltage too high/too low protection;

P2: Potection of IPM high temperature;

P3: Potection of outdoor temperature too low

(For the Cooling & Heating models);

P4: Potection of compressor location;

P7: Outdoor IGBT sensor error.

   Displays room temperature on fan only mode, displays the setting temperature on the other modes.

   Displays times during Timer setting, after 10 seconds, the system will revert back to display the setting temperature.

          as the problem may resolve itself. If not, disconnect the power, then connect it again. Turn the unit on. If the problem persists, disconnect the 

          power and contact customer service.

Turbo function

Press the “TURBO” button by remote controller on COOL mode, the air conditioner goes into powerful

 

cooling operation. Press again to cancel the TURBO function.

ECO function(

For RC-S70U, RC-S90U and RC-S120U only

)

Press the “ECO” button by remote controller on COOL mode to enter the energy efficient mode.

LED Display:

Shows Error codes(inverter type):

E0: Indoor EEPROM error;

E1: Communicaiton error between displayboard and main control;

E3: Indoor fan motor speed out of control;

E4: Room temperature sensor error;

E5: Evaporator temperature sensor error;

EC: Refrigerant leakage detection;

F0: Current overload protection;

F1: Outdoor temperature sensor error;

F2: Condenser temperature sensor error;

Shows Error codes:

 (For RC-S70U, RC-S90U and RC-S120U only)

Error code appears and begins with the letters as the following in the window display of indoor unit:EH(xx), EL(xx), EC(xx) , PH(xx), PL(xx), PC(xx).

Note:

The unit may stop operation due to a malfunction with the unit. If this occurs,an error code may appear on the display like

 belo

         

       

w.

 

Wait 10 minutes 

Air direction control

Vertical airflow adjustment(Manually)

When the unit is operating, use the hand to adjust the louvers to change the vertical airflow direction.The vertical angle of air flow can be set by 

gripping the louver and move to the desired position (see 

below

). 

Summary of Contents for RC-S70U

Page 1: ...RC S70U RC S90U RC S120U RC S180U RC S240U...

Page 2: ...Precautions 1 3 4 5 6 7 8 9 10 11 12 13 R32 IEC 60335 2 40 14 0 75 2...

Page 3: ...1 2 3 4 5...

Page 4: ...03 09 10 12 12 13 15 16 2018 12 31...

Page 5: ...3 R32...

Page 6: ...4 3 10mA RCD 30mA 1 2 3 4 5 6 7 1 3 8 9 10 11 PCB 220V...

Page 7: ...5 R32 R32 R32 IEC 60335 2 40 2018 R32...

Page 8: ...6 1 2 3 4 5 6 1 2 3 4 5 6 7 8 9 R32...

Page 9: ...7 7 1 2 8 9 10 11 LFL 25 OFN 12 OFN OFN OFN 13 OFN...

Page 10: ...8 14 a b c d e f g h 80 i j k 15 16...

Page 11: ...9 18 C 43 C 64 F 109 F 17 C 32 C 62 F 90 F 1 2 3 4 5 6 7 8 1 1 9 10 1 2 3 4 5 6 7 8 9 1 2 6 1 RC S70U RC S90U RC S120U RC S180U RC S240U...

Page 12: ...10 RC S180U RC S220U RC S70U RC S90U RC S120U 17 C 30 C 17 C 30 C 1 C 30 C 1 C 17 C RC S70U RC S90U RC S120U RC S180U RC S220U...

Page 13: ...11...

Page 14: ...12 A B 1 2 3 4 50 C 122 F 1 2 A B 3 40 C 104 F 4 5 6 90...

Page 15: ...1 3 4 2 3 3 4...

Page 16: ...6 10 11 5 5 6 7 14 8 9 1 5 2 6 1 2 A B 5 7 3 7 1 8 2 3 7 1 9 2 10 8 1 2 2 11 3 4 4...

Page 17: ...15 a b c d e f 1 a b 2 PVC c 3 d e RC S180U RC S240U 4 6 7 3 2 MED HIGH...

Page 18: ...RC S70U RC S90U 450 6x350x675 RC S120U RC S180U 660x428x780 RC S240U 16...

Page 19: ...1 0 2 0 0 3 28612767 0 0 2406 5666 o o 0...

Page 20: ...W TERRITORIES HONG KONG TEL 852 2406 5666 FAX 852 2408 0316 WEBSITE www shesc com CONSUMABLES ACCESSORIES SALES HOTLINE TEL 852 2406 5666 CUSTOM SERVICE CENTRES 2 1 1ST FLOOR SHUN HING CENTRE 2 SHING...

Page 21: ...mmable refrigerant Read this manual carefully before installing or operating Make sure to save this manual for future reference Please check the applicable models technical data from the nameplate pas...

Page 22: ...ed personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants 5 Do not use means to accelerate the defrosting process or to clean other than thos...

Page 23: ...it 1 Transport of equipment containing flammable refrigerants Compliance with the transport regulations 2 Marking of equipment using signs Compliance with local regulations 3 Disposal of equipment usi...

Page 24: ...reprocessing or recycling of abandoned REE must obtain a waste disposal licence a permit is required for the import and export of abandoned REE and abandoned REE is no longer be accepted for disposal...

Page 25: ...upervised around the unit at all times operate your air conditioner in a wet room such as a bathroom or laundry room Too much exposure to water can cause electrical components to short circuit In cert...

Page 26: ...arth wire The unit should be provided with an individual circuit and the circuit breaker fuse rating should be the same as that of the power cord and wall outlet Power cord conductors are distinguishe...

Page 27: ...t authority which authorises their competence to handle refrigerants safely in acc ordance with an industry recognised assessment specification Servicing shall only be performed as recommended by the...

Page 28: ...Ventilated area Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work A degree of ventilation shall continue during the per...

Page 29: ...ed If a leakage of refrigerant is found which requires brazing all of the refrigerant shall be recovered from the system or isolated by means of shut off valves in a part of the system remote from the...

Page 30: ...d in them Cylinders shall be kept upright Ensure that the refrigeration system is earthed prior to charging the system with refrigerant Label the system when charging is complete if not already Extrem...

Page 31: ...n the surroundings is comparatively low at night If your feel that the noise is too loud switch the thermostat to lower numbers UNIT PARTS IDENTIFICATION NOTE Different models have different front pan...

Page 32: ...he vent It will allow internal air circulation OPEN the vent to discharge stale air OPERATING INSTRUCTIONS RC S70U RC S90U RC S120U RC S180U RC S220U TEMP Sleep Timeron Timeroff TEMP CLOSE VENT OPEN C...

Page 33: ...crease the set operating temperature of the unit Each time the keypad is pressed the temperature increases as follows 1 Celsius Scale Maximum Setting 30 TEMPERATURE SETTINGS DOWN Press the keypad to d...

Page 34: ...RC S120U only Press the ECO button by remote controller on COOL mode to enter the energy efficient mode LED Display Shows Error codes inverter type E0 Indoor EEPROM error E1 Communicaiton error betwe...

Page 35: ...stall it at the postion as you like Clean it with a hand held vacuum Model B 1 2 3 4 WATER DRAINAGE ALWAYS TURN OFF YOUR AIR CONDITIONER SYSTEM AND DISCONNECT ITS POWER SUPPLY BEFORE CLEANING OR MAINT...

Page 36: ...at water will not leak from the surrounding area when rubber plug and joint were used Please seal it in case leakage is found Rubber plug Drain pan Drain outlet Screw Rubber plug Back drain hole Drain...

Page 37: ...e such as a fence or wall within 50cm from the back of the cabinet because it will prevent heat radiation of the condenser Restriction of outside air will greatly reduce the cooling efficiency of the...

Page 38: ...the cabinet remain in position See Fig 8 2 Connect the air conditioner to the power and position excess cord length beneath the air conditioner base 3 Engage the chassis fixing brackets into the botto...

Page 39: ...it the drain pan to the cabinet and run a drain hose to a suitable location if required Fig 11 17 NOTE For the unit with power cord comes out from left side please perform the following steps 1 Pull t...

Page 40: ...the air conditioner plug is pushed completely into the outlet and switched on Check the house fuse circuit breaker box and replace the fuse or reset the breaker If power failure occurs switch off and...

Page 41: ...y SPECIFICATIONS The size of the power supply cable signal cable fuse and switch needed is determined by the maximum current of the unit The maximum current is indicated on the nameplate located on th...

Page 42: ...pecifications are subject to change without prior notice for product improvement Consult with the sales agency for details Any updates to the manual will be uploaded to the website please check for th...

Page 43: ......

Page 44: ...W TERRITORIES HONG KONG TEL 852 2406 5666 FAX 852 2408 0316 WEBSITE www shesc com CONSUMABLES ACCESSORIES SALES HOTLINE TEL 852 2406 5666 CUSTOM SERVICE CENTRES 2 1 1ST FLOOR SHUN HING CENTRE 2 SHING...

Reviews: