NOTE
The compensation valve adjustment is used
to adjust fan and atomization pressure at the
same time when the pressure to run the turbine is
higher than the atomization fan pressure desired.
15. Adjust compensation valve with small driver.
FLUSHING / COLOR
CHANGE PROCEDURE
1. Turn off electrostatics.
2. Disconnect air to applicator.
OR...
3. Discharge fluid into appropriate earth grounded
metal container
4. Load next color, solvent flush and/or remove
applicator from installation as required.
W A R N I N G
!
The solvent supply must be interlocked with
the applicator supply air.
AH-17-04-R0.0 (11/2017)
23 / 59
www.carlisleft.com
OPERATION