31
INSTALLATION
Check the appliance is electrically safe and gas sound when you have finished.
Conversion to LP gas
Check in the Technical Data section at
the back of the book that the cooker is
convertible to the gas you want to use.
This conversion must be performed by a competent
person. After conversion the installation must comply
with the relevant regulations and also the local
electricity supply company requirements. Read the
instructions before converting this appliance.
Failure to convert the appliance correctly could
invalidate any warranty or liability claims and lead to
prosecution.
This instruction must be used in conjunction with the rest
of the appliance instruction, in particular for information on
Standards, cooker positioning, connection hose suitability
etc.
When servicing or replacing gas-carrying components
disconnect from gas before commencing operation and
check appliance is gas sound after completion.
Do not use re-conditioned or unauthorised gas controls.
Disconnect from the electricity supply before commencing
servicing. Before electrical re-connection, check that the
appliance is electrically safe.
Jets
Remove burner caps and heads. Remove old jets. Fit new
jets (see the table for the correct jets). Reassemble in
reverse order.
Tap )adjustment
Pull off all the control knobs.
Remove the 3 screws at the rear of the top edge of the
control panel.
Open the oven doors and remove the 2 fixing screws, one at
each end, underneath the control panel.
Pull the control panel forward and disconnect the wiring
from the rear.
Remove the shield covering the control taps (2screws).
A tap bypass screw
Remove the tap bypass screw and replace with the correct
screw. See the table for the correct bypass screws.
Stick on label
Stick the appropriate label on to the data badge to indicate
the gas the appliance is now set for.
Pressure Testing
Connect the appliance to the gas supply. Check the
appliance is gas sound.
The gas pressure can be measured at one of the centre
hotplate burner injectors (not the Wok burners). Lift off a
burner head. Fit the pressure gauge to the injector. Turn
on and light one of the other hotplate burners. Press in the
control knob for the burner with the pressure gauge fitted
to let gas through.
Reassemble burner top, making sure it is reassembled in the
correct way on the burner body.
Refit the control tap shield. Reconnect the wiring to the
control panel and refit the panel.
Check the appliance is gas sound.
Check operation of all the burners.
Check that the appliance is electrically safe.
I2H
I3+
G20
G30
G31
20mbar
29mbar
37mbar
A1
80
54
A2
129
77
kW
3.65
3.5
g/h
255
B
134
87
kW
3.0
3.0
g/h
218
C
109
68
kW
1.7
1.7
Summary of Contents for Elite 110 Dual Fuel
Page 1: ...Elite 110 Dual Fuel Users Guide Installation Service Instructions U103900 10...
Page 2: ...2...
Page 40: ......