Error Codes
R&S SM300
Version 04
102
Service Manual SM300: 1147.1652.00
Instrument Part No SM300: 1147.1498.03
5.2.3.2 Power Supply Module
EventId
Description
Parameters
Parameter Description
0×6150
Event_Monitor
See Table 5-7: Additional information about
event monitor (event 0×6050) parameters
0×6130
PASSWORD
int16
0×80 – Good_Pwd
0×81– Bad_Pwd
0×6140
BOOT_EVENT
Transmission of errors at boot time (errors
defined in ose_user_errors.h)
0×6160
SHUTDOWN
uint16 SHUTDOWN
Indicates to host that the system is going
down (SHUTDOWN=1)
0×6170
SERIAL_
TRANSFER_
HANDSHAKE
uint16 SERIAL_
TRANSFER_HANDSHAKE
Indicates that a serial transfer was cancelled.
(ACK=0×33 (acknowledge),
NAK=0×CC (not Acknowledge),
RST=0×66 (reset)
Handshake signals sent from the STPC and
transferred via the PS:
FS_TOO_BIG=0×C0 (file size too large)
FS_DEST_ERR=0×C1 (destination error)
FS_PACK_ORD=0×C2 (packet order error)
FS_HEAD_ERR=0×C3 (header error)
(FS_EX_RDY=0×C4 (execution ready)
FS_TIME_OUT=0×C5 (receiver timeout)
FS_PS_NOT_RDY=0×C6 (power supply not
ready to send serial data)
FS_FILE_EXIST=0×C7 (file exists)
0×6180
HW_ERROR_
EVENT
0×6190
USB_CHANGE_
EVENT
Enum eUSB_Master
Values are:
PC_Master = 0
Display_Master = 1
Interface_Master = 2
No_Master = 3
0×6110
USB_CHANGE_
AUTO
0×ffff
If this event occurs, the system was in the
USB auto mode and the external PC was
plugged-in.
0×6120
OVER_
TEMPERATURE_
PS
–
Overtemperature of the power supply
0×6121
OVER_
TEMPERATURE_
MODULE
–
Overtemperature of a module
0×6191
BATTERY_
NOT_SUPPORTED
–
The command to read the battery was
rejected because no battery is installed.
Table 5-6: Power Supply Module