Troubleshooting
R&S XU 4200
4.7
6166.5368.02.01
Code Message Level
Config
Note
Action
0110 MMI
PART
a b c
W – Information
about
booted MMI FW and
device FW validity:
a = currently booted
partition, i.e. ‘1’ or ‘2’,
b = version number,
e.g. ‘10.xx’,
c = comparison result
defined as a bit-wise
mask (little endian),
where:
bit 0 set – comparison
fail, currently booted
partition numbers not
equal,
bit 1 set – comparison
fail, part numbers not
equal,
bit 2 set – comparison
fail, version numbers
not equal.
E.g. ‘0’ for case of
comparison passed or
‘6’ for case when
currently booted
partition numbers are
equal on MMI, TX and
RX, but part numbers
and version numbers
are not equal on at
least two modules.
This event is for
information only (see
chapter 4.2.3).
0201
PSU FAN WARNING
W
N
Rotation speed of the
PSU fan is low.
Check airflow of fans and
clear the ventilation
opening.
Check the internal PSU
temperature (see chapter
determine whether
operation can be
maintained for a certain
time (see chapter 5.2).
If this fails to eliminate
the fault, send the radio
to service.
0202
PSU FAN ERROR
E
–
PSU fan is not running
or is blocked.
Send the radio to service.
Summary of Contents for 4200 Series
Page 4: ...R S XU 4200 6166 5368 02 01 0 2...
Page 10: ...R S XU 4200 6166 5368 02 01 0 8...
Page 16: ......
Page 18: ......
Page 22: ......
Page 23: ......
Page 24: ......
Page 25: ......
Page 26: ......
Page 27: ......
Page 28: ......
Page 32: ......
Page 34: ...R S XU 4200 6166 5368 02 01 0 18...
Page 36: ...R S XU 4200 6166 5368 02 01 0 20...
Page 166: ...R S XU 4200 Software Download 6166 5368 02 01 3 114...