Troubleshooting
6166.5368.02.01 4.10
Code Message Level
Config
Note
Action
0317
PA TEMP WARNING
W
–
Temperature on the PA
module is over the
warning limit (80 °C).
Output power is
reduced step by step.
This behavior is normal
with continuous
operation and +55 °C
ambient temperature.
Check airflow of fans and
ambient temperature
(see chapter 5.2).
Clear the ventilation
opening.
Check the antenna, and
measure VSWR (see
chapter 3.4.7.4.1). A high
VSWR may cause a
heavy power loss in the
transmitter.
0318
PA TEMP ERROR
E
–
Temperature on the PA
module is over the error
limits (95 °C).
Transmitter is switched
off.
Send the radio to service.
0319
TX TEMP WARNING
W
–
Temperature on the TX
board is over the
warning limit (70 °C).
Output power is
reduced step by step.
This behavior is normal
with continuous
operation and +55°C
ambient temperature.
Check airflow of fans and
ambient temperature
(see chapter 5.2).
Clear the ventilation
opening.
0320
TX TEMP ERROR
E
–
Temperature on the TX
board is over the error
limit (85 °C).
Send the radio to service.
0321
PA NO OUTPUT
PWR
E
–
Output power is less
than 500 mW.
Send the radio to service.
0322
PA POWER LOW
–1 DB
W –
Output
power
decreases by 1 dB.
Check temperature (see
chapter 3.4.7.4.4)
Check VSWR (see
chapter 3.4.7.4.1)
Check DC voltage (see
chapter 3.4.7.4.3).
See CBIT messages
0325 to 0328.
If this fails to eliminate
the fault, send radio to
service.
Summary of Contents for 4200 Series
Page 4: ...R S XU 4200 6166 5368 02 01 0 2...
Page 10: ...R S XU 4200 6166 5368 02 01 0 8...
Page 16: ......
Page 18: ......
Page 22: ......
Page 23: ......
Page 24: ......
Page 25: ......
Page 26: ......
Page 27: ......
Page 28: ......
Page 32: ......
Page 34: ...R S XU 4200 6166 5368 02 01 0 18...
Page 36: ...R S XU 4200 6166 5368 02 01 0 20...
Page 166: ...R S XU 4200 Software Download 6166 5368 02 01 3 114...