R&M Materials Handling, Inc
STAGEMAKER
®
Concert Hoist
Springfield, Ohio USA
Technical Guide
:
800 955-9967
June 2009
www.rmhoist.com
RM-STGMKR-TG-2002-6-ENG.doc
24
®
4.4 Pushbutton Pendant Controller for Configuration B (SM16 – SM25) or D
The pushbutton pendant controller can be suspended from the hoist and is available for the SM16, SM20
and SM25 models and for the Configuration D hoist controller.
Features:
Pendant cord length matches hoist height of lift without plug
Pushbutton enclosure ratings of IP65 (NEMA 4 Type)
Suitable for indoor or outdoor use
Pendant station is light in weight for easy handling and operation
Strain relief
Emergency Stop is a push-to-maintain, turn-to-release, red mushroom head button
Two push buttons for each motion, one for each direction of travel
Contacts for motion buttons are mechanically interlocked and momentary type
Optional Features:
Longer cable lengths
Plug
4.5 Programmable Controller for Configuration C
Third-party controller
4.6 Controller for Configuration D
These controllers are designed specifically for the Configuration D hoist and provide a complete BGV-C1
package. The control functions are on the controller. A remote with a GO button (run command) and E-
stop is available as an option.
Model
Number of
channels
Description
Enclosure
Connection
B2PRMLV-C1
2
Low voltage c controller Wall mount
16 pin Harting
R4PRMLV-C1
4
Low voltage c controller 19” 6U rack in flight case
16 pin Harting
R8PRMLV-C1
8
Low voltage c controller 19” 6U rack in flight case
16 pin Harting
R12PRMLV-C1
12
Low voltage c controller 19” 6U rack in flight case
16 pin Harting
Specification:
Low voltage (48 VAC) control, Configuration D hoists, a BGV-C1 controller
The control circuit of the mainline contactor in the hoist control panel becomes part of the
RxPRM type controller.
Single hoist up to 1.44HP [1.1kW] per channel at 230V-3Ph-60Hz
3 position selector switch (UP-OFF-DOWN) per channel (group control)
One GO (run command) button (effective only on channels selected via selector switch)
Emergency Stop
Short circuit proofing: once at 10kA maximum
Individual level correction
Phase inversion capability on incoming CE plug
Connection cable (2 ft length) for interconnection between controllers
Available Options:
Flight cases of different sizes for one, two or three racks
Remote with a GO button and E-stop
4.7 Controller for Configuration E
Third-party controller