3.4 Hoist Configuration D – BGV-C1 Enhanced Safety Features
Configuration D utilizes three-phase power, low voltage control and must be operated with
STAGEMAKER
®
R8PRM-C1 controller (see Note). The hoist complies with enhanced safety regulations
in accordance to DIN 56925. The hoist is mounted in the normal position, but when specially equipped,
the hoist can also be mounted in the inverted position and must be operated from a nonprogrammable
controller.
Hoist features:
Black load chain
Non-reflecting matt black finish
Fixed body hook
Standard chain guide
Two brakes
Torque limiting device
Low voltage (48 VAC) control with mainline contactor
(1)
Steel control enclosure
Geared limit switch – four position
Electronic type overload device
Connection pigtail with a Harting or equal (16 pin + ground) metallic male plug for control and
power (standard pigtail length is 18”, longer lengths available)
Diagnostic test plug
Capacity de-rated by 50% from standard
Chain container for 100 ft [30 m] of chain
Electronic overload relay
Test facility for brakes and limit switches
230V-3Ph-60Hz + neutral power supply
(1)
Operation of the main line contactor is taken over by the controller.
Available options:
Inverted mounting position - includes a Chainflux chain guide, handgrips, and a swiveling
body hook
Swiveling body hook
Self locking hook
Vinyl rain cover
Drain hole in the load sprocket compartment
Hoist motor thermal protection
208V-3Ph-60Hz + neutral power supply
Handgrips
Controllers:
STAGEMAKER
®
8 channel R8PRM-C1 controller
Pushbutton controller with E-stop button
Accessories:
Motor cables
Note:
For group control of BGV-C1 hoists, the use of the R8PRM-C1 controller is mandatory. For
single hoist applications, the hoist could be used without any restrictions. It just needs a
pushbutton controller (pickle) with E-stop.