The picture below shows the connections:
4.2
Connection of the rail collector
In a two- rail-loco connect the lines of the two current collectors with
either of the two solder points with the
label ‘Rail’.
In a three-rail-loco, connect the locomotive ground with one of the
two solder pads
called ‘Rail’. Connect the grinder with the remaining
solder pad.
Note: The polarity of the digital signal is automatically detected by the
decoder.
4.3
Connecting the motor
Check before installation of the decoder, if the maximum current of
the locomotive motor under load is below the maximum permissible
value of 1.000 mA. If the value is above 1.000 mA, this decoder is not
suitable for installation in the locomotive. The decoder has an over-
current shutdown, which is activated, if the maximum permissible mo-
tor current is exceeded.