Loco-1 / Loco-2
V1.1 - English
page 27 of 36
CV / Register
Name
CV
Register
Loco
-1 / -2
Range
(default)
Note
Dimming
value
AUX1
…AUX4
47
…
50
35 / 34
0 … 100
(100)
Value in % with which the output is dimmed
Decoder
settings
51
39 / 38
0 … 255
(128)
Bit 0: Motor type
0
– DC motor
1
– AC (Marklin®) motor
Bit 1: Motor PWM frequency for DC-motor
0
– 15,625kHz
1
– 31,25kHz
Bit 2: function mapping
0
– normal
1
– extended
Bit 3: Function decoder mode
0
– Loco decoder 1 – Function decoder
Bit 7: automatic detection of motor type
0
– off
1
– on
Bit 4 - 6: not used
Decoder
temperature
52
40 / 39
0 … 100
Maximum measured temperature of the decoder in
°C. Can be reset by writing the value
‘0'.