background image

26

Adjac

ent w

all

Adjacent wall

Back wall

Side w

all

Clearances to combustible surfaces

**Rear/Top vent option

Ceiling

**

FLOOR PROTECTOR

See further floor protection

requirements at bottom of 

this label.

 

Floor protection for

Canada: 18" (45 cm)

from unit to front of floor protector.

 

Floor protector must be under the 

pipe and 2" 

(5cm) beyond each side for back 

venting.

U.S. ENVIRONMENTAL PROTECTION 

AGENCY Certified to comply with 2020 

particulate emission standards using crib 

wood.  0.7 g/hr, Method 28R

MINIMUM CLEARANCE                                      

                                                   Top Vent        Rear Vent

A: SIDE WALL TO UNIT                  14"/356mm    14"/356mm

B: BACK WALL TO UNIT                 12"/305mm    12"/305mm

C: CORNER WALL TO UNIT           11"/280mm     N/A

D: CEILING HEIGHT                       45"/1143mm   45"/1143mm

E: FRONT WALL / FURNISHING:   36"/915mm     36"/915mm

F: Back Wall to Pipe                       15"/381mm      N/A

G: Side Wall to Pipe                     22,5"/572mm     22,5"/572mm

H: Corner Wall to Pipe                    20"/508mm      N/A

 

Do not store wood logs or combustible materials underneath the room heater

Écartement minimum                                   

                                                

évent supérieur   Évent arrière

A: Mur latéral - Appareil             14"/356mm        14"/356mm

B: Mur arriére - Appareil             12"/305mm        12"/305mm

C: Mur de coin - Appareil           11"/280mm         N/A

D: Plafond - Lappareil               45"/1143mm        45"/1143mm

E: Distance meuble devant       36"/915mm          36"/915mm

F:  Paroi arrière de cheminée    15"/381mm          N/A

G: Paroi arrière de cheminée  22,5"/572mm         22,5"/572mm

H: Coin mur pour cheminée       20"/508mm         N/A

 

Ne pas stocker les journaux de bois ou des matériaux combustibles sous le radiateur de la chambre

FLOOR PROTECTION:

 

Floor protection must be non-combustible material 

extending beneath the stove,

and to the front and sides from door opening and to the 

rear as indicated. 

The floor protection is not required to have thermal 

protection (R=0)

 

** Not Tested - NFPA Guidelines in USA, CAN/CSA 

B365-M91 in Canada

** Non testé - NFPA Guidelines au USA, CAN/CSA 

B365-M91 au Canada

 

La protection de sol doit être au moins de 3/8 inch 

matériel non combustible placé sous le foyer 

s'étendant vers l'avant, les côtés les ouvertures et 

l'arriére comme induqué.

Manufactured by:

RAIS A/S

Industrivej 20, DK-9900 Frederikshavn, Denmark

Model: Q-Tee II C SST USA

Solid Fuel Room Heater

Tested to:

UL 1482-2022

ULC S627-2023

For Use With Solid Wood Fuel Only

Model

Modéle

Date of manufacture        Month

Date of fabrication            Mois

 

Year

Année

Serial no.

N° de série

      Safety Report No. # 23-202

Emissions Report No. #  300-ELAB-2635-EPA Rev 1

Made in Denmark

Fabriqué au Danemark

Front

8"

8"

8"

16"

This wood heater needs periodic 

inspection and repair for proper 

operation. Consult the owner's manual for

further information. It is against federal 

regulations to operate this wood heater in

a manner inconsistent with the operating 

instructions in the owner's manual.

2"

A

B

E

F

G

C

H

C

H

D

To be installed as a freestanding room heater with the clearances in the

manufacturer's installation instructions. Not to be installed in any 

factory-built fireplace."

Do NOT obstruct the space beneath the heater!

Combustion air openings are NOT to be obstructed!

Replace glass with only Rais authorized dealer supplied ceramic glass

 

À installer comme radiateur d'ambiance autonome avec les dégagements 

dans le

instructions d'installation du fabricant. Ne doit pas être installé dans un 

foyer préfabriqué.

N'obstruez PAS l'espace sous le radiateur !

Les ouvertures d’air de combustion ne doivent PAS être obstruées !

Remplacez le verre par du verre céramique fourni uniquement par un 

revendeur agréé Rais.

US

**: 
Please refer to NFPA guidelines in 
USA and CAN/CSA B365-M91 in 
Canada. 

Summary of Contents for Q-Tee 2 C Soapstone

Page 1: ...U S E R M A N UA L M A N UA L D U T I L I SAT I O N Q Tee II C SST USA...

Page 2: ...tivelighting Usesmallpiecesofwood firtree andasuitable fire lighter for example paraffined wood wool sawdust Open the air damper so plenty of air is fed to the stove and the gases from the heated wood...

Page 3: ...TOR PASS THROUGHS IN COMBUSTIBLE WALL 19 MASONRY CHIMNEY 21 FACTORY BUILT CHIMNEY 22 FLOOR PROTECTION 23 CLEARANCES TO COMBUSTIBLE WALLS 25 CLEARANCES TO NON COMBUSTIBLE WALLS 27 REDUCED CLEARANCES CA...

Page 4: ...ture constructed on skids or run ning gear WARNING Do not overfire If the stovetop or chimney connector pipe glow red you are overfiring Warning Do not use other than the specified original Rais compo...

Page 5: ...utput BTU hr 11600 20005 Minimum stove draft pressure at above output 0 048 WC 12 Pa Tested EPA emission particulate rate 0 7 g hr Specifications U S ENVIRONMENTAL PROTECTION AGENCY Certified to compl...

Page 6: ...6 A A A A 970 38 189 in n 1 7 0 n 6 6 9 3 in 179 7 047 in 696 27 402 in 511 904 20 154 in Q Tee II C SST USA Steel door 8286550 1038 40 866 in 1070 42 126 in 110 4 331 in 850 33 465 in US...

Page 7: ...7 A A A A 970 0 418 540 963 978 1038 1070 362 417 0 110 380 850 1070 n 170 179 696 512 R748 R 1 4 3 0 Q Tee II C SST Glass door 8289002 0 205 454 US...

Page 8: ...he floor protection is not required to have thermal protection R 0 Not Tested NFPA Guidelines in USA CAN CSA B365 M91 in Canada Non test NFPA Guidelines au USA CAN CSA B365 M91 au Canada La protection...

Page 9: ...CAUTION Only operate the wood heater with the doors closed To be installed as a freestanding room heater with the clearances in the manufacturer s installation instructions Not to be installed in any...

Page 10: ...integral part of the door and stove Inspect the glass for cracks prior to the first fire Abuse may cause damage to the glass and door Do not strike the door or glass nor slam the door Do not build the...

Page 11: ...11 US Production number The production number can be found on the back of the stove Name tag The name tag can be found on the back of the stove...

Page 12: ...ve is secured to a transport pallet using four transport safety fittings one in each corner A The safety fittings are secured with screws which must be unscrewed The safety fit tings can then be remov...

Page 13: ...ndle 1 2 3 B 0 5 4 2 3 US FITTING CHANGING THE HANDLE The wood burning stove comes with a temporary handle 1 To remove it undo the screws and washers 3 2 The new handle 4 can now be fitted to the stov...

Page 14: ...red M6 nuts and bolts Rear outlet The stove can be changed to rear outlet in the following way 1 On the back of the stove there is a knock out form that must be knocked free of the back It is attached...

Page 15: ...g of Heat shield The Heat shield is not mounted to the stove on delivery and must be mounted before the stove is put into use Step 1 Mount the distance piece 1 to the back of the wood stove Step 2 Mou...

Page 16: ...ea If utilizing an existing chimney it is recommended that a professional mason or wood stove installer do a complete check up of the chimney liner and flue beforehand In order for the wood stove to w...

Page 17: ...ved masonry chimney with a flue liner In Canada the ap pliance must be connected to a factory built chimney conforming to CAN ULC S629 The chimney pipe must be 6 in diameter The chimney must extend th...

Page 18: ...door For venting vertically into a Class A chimney a single wall pipe at least 24 gauge may be used in the room where the stove is installed Refer to the manufac turer s instructions for the connectio...

Page 19: ...ey connector pass throughs in combustible wall Method B 9 228 6 mm Clearance to Combustible Wall Member Using a 6 152 4 mm inside diameter listed factory built Solid Pak chimney section with insula ti...

Page 20: ...with a solid pak listed factory built chimney section at least 12 304 mm long with insulation of 1 25 4 mm or more and an inside diameter of 8 2 inches 51 mm larger than the 6 152 4 mm chimney connect...

Page 21: ...ssociation BFPA by having it inspected by a professional Make sure there are no cracks loose mortar or other signs of deterioration and blockage Have the chimney cleaned before the stove is installed...

Page 22: ...anufacturer and install the ceiling sup port package or wall pass through and T section package firestops where needed insulation shield roof flashing chimney cap etc Maintain proper clearance to the...

Page 23: ...t material specifications to R value a R value given no conversion necessary b K factor is given with a required thickness T in inches R 1 k x T c C factor is given R 1 C 2 Determine the R value of pr...

Page 24: ...618 and is not required to have thermal protection R 0 Make sure that the floor and the sub floor of the room in which the stove is installed is designed to carry the extra weight of the stove The flo...

Page 25: ...tove is to be placed is combustible or not please contact your architect or the local building authorities If the floor is combustible the stove must be placed on a non combustible plate such as steel...

Page 26: ...l 12 305mm 12 305m C Mur de coin Appareil 11 280mm N A D Plafond Lappareil 45 1143mm 45 1143 E Distance meuble devant 36 915mm 36 915m F Paroi arri re de chemin e 15 381mm N A G Paroi arri re de chemi...

Page 27: ...Code for Solid Fuel Burning Ap pliances and Equipment any combustible covering beneath the appliance and or within the area extending horizontally at least 450 mm 18 in beyond the appliance on any si...

Page 28: ...le supports spaced out at least 21 mm 7 8 in by non combustible spacers Ceramic tiles or equivalent non combustible material on non combustible supports with a minimum of 29 gauge sheet metal backing...

Page 29: ...y per pound however the density of wood is not the same as is shown in the table below where the combustible value of wood dried for two years with a moisture of 15 20 is taken into account See table...

Page 30: ...the glass The warm air runs along the glass keeping it free of soot At the very back of the combustion chamber there is a tertiary channel at the top that helps to combust the remaining gases When po...

Page 31: ...on the handle is to be adjusted to the interval between pos 1 and 2 When the flames are clear and yellow the damper has been adjusted correctly resulting in slow opti mal combustion Position 3 Pull th...

Page 32: ...ol ing down the metal may emanate some clicking sounds due to being exposed to the large differences in temperature This is normal as well For wood to burn properly the right amount of air has to be s...

Page 33: ...ull not to place the firewood too close to the opening and glass TIPS before firing up Open a door or window close to the wood burning stove If there is wind in the stove coming from the chim ney it i...

Page 34: ...l not to place the firewood too close to the opening and glass Leave the door ajar until the fire has caught on properly close the door After approx 5 min or when the flames are clear and stable close...

Page 35: ...king or repairing the stove must be cold If the glass has been covered in soot here is a simple piece of advice Dampen a piece of paper or newspaper dip it into the cold ashes and rub the soot covered...

Page 36: ...need to clean to be safe Be aware that the hotter the fire the less creosote is deposited and weekly cleaning may be necessary in mild weather even though monthly cleaning may be enough in the coldest...

Page 37: ...the fireplace insert The lining will only need be replaced after several years of use when it begins to disintegrate The liner panels are easy to place in position in the fireplace insert and can easi...

Page 38: ...II C SST USA Lubricating the moving parts 8286510 US LUBRICATING THE HINGES LOCK The fireplace must be lubricated regularly using the three moving parts on the lock and hinges see image Use heat resis...

Page 39: ...e and turning it a little slantwise Pull out the plate carefully Then remove the smoke impediment by lifting it up and moving it forward Carefully lift out the smoke impedi ment There is now an unbloc...

Page 40: ...th time small cracks might appear this is normal If it breaks however it must be replaced Vermiculite is a porous high insulat ed material and must therefore be handled with care Creosote Formation an...

Page 41: ...low The stove burns too quickly Gasket may not be tight please check and replace if necessary Chimney draft maybe too high 22 Pa if this is the case please install a damper The stove is burning too s...

Page 42: ...er manual Pos PCS Item number Description 1 1 8341190 Steel door 2 1 8341090 Glass door 3 1 8422200USA Fire brick set 4 1 8423800USA Shaking grate 5 1 8384001 Ash pan 6 1 838121090 Air guiding plate 7...

Page 43: ...43 12 1 2 5 4 7 6 3 8 9 9 11 13 14 16 15 US Spare parts...

Page 44: ...ttom cover must be removed 1 Replace the two screws holding the air damper with the stand offs delivered with the air box 2 Slide the air box 1 under the burning chamber make sure that the back end of...

Page 45: ...flex hose 2 to the air nozzle 1 with the hose clamp 4 5 Connect the flex tube 2 to the air valve 3 using a hose clamp 4 AIR KIT FRESH AIR SUPPLY AIR THROUGH THE BOTTOM When the space heater is instal...

Page 46: ...RAIS A S Industrivej 20 DK 9900 Frederikshavn Denmark www rais com OUTLINE NEGATIV...

Page 47: ...05 2023 4 15 05 2023 5 05 08 2023 6 28 09 2023 sparepart list updated with new part numbers for firebrick set and shaking grate Section on Smoke and carbon monoxide detectors added Label changed accor...

Reviews: