17
US
Each chimney connector or stove pipe section, must be installed to each other with
the crimped end toward the stove. This prevents any amount of condensed or liquid
creosote from running down the outside of the pipe or the stove top.
Fasten the connector pipe to the flue collar with 3 self tapping/drilling screws through
the holes in the flue collar.
Male
smok
e dir
ection
Female
Chimney
RAIS stoves must be installed using a Class A UL 103 HT approved factory-built chim-
ney system or a code-approved masonry chimney with a flue liner. In Canada, the ap-
pliance must be connected to a factory-built chimney conforming to CAN/ULC-S629.
The chimney pipe must be 6” in diameter.
The chimney must extend through the roof at least 3’ (1m), and 2’ (.6m) above any
structure within 10’ (3m).
The condition and height of the chimney are very important for optimal use of the
stove and we recommend a total minimum height of 10’ (3m).
The stove is delivered with a 6” flue collar (Rais part number 61-110)
Note the chimney connector pipe should not pass through an attic, roof space, closet,
concealed space, floor or ceiling.
Do not connect this stove to a chimney flue or air distribution duct or any system
serving another appliance.