Setting the start times

You can set up to eight start times for each program, but it is not necessary for you to
use all eight start times with each program. After you enter all the start times, the
transmitter will automatically organize the start times in chronological order, from
00:00 to 23:59 or 12:00 AM to 11:59 PM.

To set the start time:
1. Make certain the      icon is visible on the display.

If it is not, press        repeatedly to cycle through the
menu system and display the      icon.

2. Press      repeatedly until the program you desire (A, B, or C) appears in the dis-
play.
3. Use       and      to set the first start time.
4. Press      to move to the next start time.
5. Repeat steps 3 and 4 until you have set all of the start times you desire (up to eight 

per program) for the program.

6. If you would like to set start times for additional programs, press       until the pro

gram you desire is displayed. Then repeat steps 3 and 4.

7. When you have finished setting the start times, press         to move to the      icon, 

Setting the Watering Time Length display.

Deleting a start time

To delete a start time:
1. Press        to advance to the      icon.

2. Press      to change to the appropriate program.

3. Press      to scroll through the start times and decide which one to delete (the start 

times will be in chronological order).

4. Again, scroll through the start times and pause on the start time just before the time 

you wish to delete.

5. Press and hold     . The start time will flash momentarily on the display, signaling its 

cancellation, and then change to --.--.

Note:

 

It is a common misunderstanding that a start time of 00:00 is “off.” It is 

actually a midnight start time. An “off” time is indicated by --.-- in the display.

Setting the run time per station

You can set the run time for each station from 0 to 12 hours (in one minute incre-
ments). All One Station Control Modules must be programmed on station 1. Multi-
station Control Modules (Two Station and Four Station) must be programmed starting
on station 1. For example, on a Four Station Control Module, programming would start
on station 1, then station 2, 3 and 4.

Summary of Contents for UNIK Field Transmitter

Page 1: ...UNIK irrigation system family allows you to create transmit and retrieve irrigation programming information when used with the UNIK Control Module The Field Transmitter features include One minute to...

Page 2: ...isplays one display at a time by pressing All of the displays except the start up display have icons representing the function that you can program while in that display LCD display icons 1 Program A...

Page 3: ...r type 6LR61 European standard We recommend that you use a high quality alkaline battery such as Energizer A high quality battery will last one year To install the battery 1 Remove the screws that sec...

Page 4: ...the display shows PM Important When you change the batteries in the Field Transmitter the time reverts back to the 24 hour dis play Setting the current day The days are indicated by a number for examp...

Page 5: ...ur watering programs Setting the water days You must select the days of the week that you want to water for each program If there is a square around the day watering will occur on that day If the day...

Page 6: ...finished setting the start times press to move to the icon Setting the Watering Time Length display Deleting a start time To delete a start time 1 Press to advance to the icon 2 Press to change to th...

Page 7: ...times Note If there is an overlap on the same station the second run time will not take place 7 When you have finished setting the run times you may review the run times by pressing Erasing Field Tran...

Page 8: ...cause there may be a difference in the current time between the two devices However when you transmit download a program to a Control Mod ule the Field Transmitter synchronizes the Control Module s cu...

Page 9: ...ou will see the icon indicating that the Control Module will water according to current programming l If the On off Mode is activated you will see the indicating that all Con trol Module programs have...

Page 10: ...ss to stop any stations that may be watering If a station is in operation a manual start is impossible A station may be in operation at the module level but without any irrigation in the field This is...

Page 11: ...d to the program will oper ate in sequence until the last station has finished watering Irrigation will then stop 5 If you wish to stop watering before the manual cycle has completed press Maintaining...

Page 12: ...eplace the battery Possible cause The microprocessor has locked up Solution Remove the battery Short the UNIK Field Transmitter battery clip not the battery contacts together with a paper clip or othe...

Page 13: ...he wires to make sure they are secure If the insulation has been stripped re cut the wires and re peat the steps above Possible cause The UNIK Rain Shut off Device is wet Solution Flip the UNIK Rain S...

Page 14: ...eption which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna...