background image

10

Performing Manual Starts and Stops

Important:

 

Before you perform manual starts and stops, you must verify the 

status of the Control Module’s irrigation status. See Verifying the On-off 
Mode, on page 9 (previous page).

Note: 

The manual functions described below override all other functions 

(except On-off); any program currently running will be suspended to permit 
their use. Manual starts and stops only affect an existing station run time or 
program.

Important:

 

Manual operations will not work if the On-off Mode is activated.

Starting a Control Module manually

You can perform either a single-station or a cycle (multi-station) manual start. Before
carrying out either type of manual start, make sure you have programmed a run time
of at least one minute and that the Control Module’s On-off Mode is not activated.

Performing a manual single-station start

If you would like to manually start one station:

1. Press         until the       icon is displayed.

The station number will also be displayed.

2. Press       to stop any stations that may be watering. If a station is in operation, a 

manual start is impossible. A station may be in operation at the module level, but 
without any irrigation in the field. This is what occurs when the Rain Shut-off De

vice prevents programmed irrigation.

3. Press       until the station you would like to start is displayed.

4. To start a station, press       . Irrigation will start after 20 seconds if you are using an 

old type Control Module. If you are using a new type Control Module (a Control 
Module with a yellow wire loop), irrigation will start after 10 seconds.

5. If you wish to stop watering before the programmed time is up, press       .

Performing a manual cycle start

If you are using an old type Control Module, the
manual cycle start option is only available on the
Two and Four Station Control Modules. If you are
using a new type Control Module (a Control Module
with a yellow wire loop), the manual cycle start option
is available on all Control Modules (One, Two and Four
Stations). The cycle consists of all of the stations operating
in sequential order.

To manually perform a cycle start:

1. Press         until the            icon is displayed.

Prog A, B or C also appears in the display.

CYC

Summary of Contents for UNIK Field Transmitter

Page 1: ...UNIK irrigation system family allows you to create transmit and retrieve irrigation programming information when used with the UNIK Control Module The Field Transmitter features include One minute to...

Page 2: ...isplays one display at a time by pressing All of the displays except the start up display have icons representing the function that you can program while in that display LCD display icons 1 Program A...

Page 3: ...r type 6LR61 European standard We recommend that you use a high quality alkaline battery such as Energizer A high quality battery will last one year To install the battery 1 Remove the screws that sec...

Page 4: ...the display shows PM Important When you change the batteries in the Field Transmitter the time reverts back to the 24 hour dis play Setting the current day The days are indicated by a number for examp...

Page 5: ...ur watering programs Setting the water days You must select the days of the week that you want to water for each program If there is a square around the day watering will occur on that day If the day...

Page 6: ...finished setting the start times press to move to the icon Setting the Watering Time Length display Deleting a start time To delete a start time 1 Press to advance to the icon 2 Press to change to th...

Page 7: ...times Note If there is an overlap on the same station the second run time will not take place 7 When you have finished setting the run times you may review the run times by pressing Erasing Field Tran...

Page 8: ...cause there may be a difference in the current time between the two devices However when you transmit download a program to a Control Mod ule the Field Transmitter synchronizes the Control Module s cu...

Page 9: ...ou will see the icon indicating that the Control Module will water according to current programming l If the On off Mode is activated you will see the indicating that all Con trol Module programs have...

Page 10: ...ss to stop any stations that may be watering If a station is in operation a manual start is impossible A station may be in operation at the module level but without any irrigation in the field This is...

Page 11: ...d to the program will oper ate in sequence until the last station has finished watering Irrigation will then stop 5 If you wish to stop watering before the manual cycle has completed press Maintaining...

Page 12: ...eplace the battery Possible cause The microprocessor has locked up Solution Remove the battery Short the UNIK Field Transmitter battery clip not the battery contacts together with a paper clip or othe...

Page 13: ...he wires to make sure they are secure If the insulation has been stripped re cut the wires and re peat the steps above Possible cause The UNIK Rain Shut off Device is wet Solution Flip the UNIK Rain S...

Page 14: ...eption which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna...