2. IMPORTANT INFORMATION

4

CLASSIFICATION ACCORDING TO

THE DIRECTIVE OF PRESSURE

EQUIPMENTS.

PED 97/23/CEE: Art. 3.3 – Fluid

Group 2

Rain Bird filtration equipment has been designed to filter water, in accordance with the operating
conditions outlined in this manual and the label on the equipment.

• Rain Bird filtration systems are NOT designed for the filtration of hazardous liquids (such as those

specified in section 2 of article 2 of the Executive Committee 67/548/CEE, 27th June 1967) or liquids
for food use.

• This equipment has been designed and manufactured to satisfy the requirements communicated to

the manufacturer by the customer. Any change in its use could cause damage not covered by the
warranty.

• Save this manual so the user of the equipment can familiarize themselves with it.

• These are general instructions for safe operation of the equipment. These instructions are not a

complete list; the user must adopt as many security measures as necessary to guarantee their
safety.

Follow the instructions described in this manual.

Do not open the filter clamp when the equipment is pressurized, it could cause serious  injury to

people, the equipment or to the surrounding area.

Do use adequate personal protective equipment (proper working clothing, safety glasses, steel toed

boots  and other elements of personal protection).

Determine the chemical compatibility between the equipment's materials and the characteristics of

the water to be filtered.

Before using the equipment, make sure that all the covers are properly closed and the connections

are in good condition.

Make sure that the equipment is depressurized by reading the gauges (0 PSI)  on the filters inlet and

outlet manifold before exposing the interior of the equipment to  atmosphere (before opening any
filter, removing any coupling, etc.)

• Do not forget to close the safety lock on the clamp. It will prevent its accidental opening.

• Do not exceed the maximum pressure or operation intervals (pressure, temperature,  PH, and flow

rate) indicated in the Technical Data.

• In freeze areas, empty the filtration system to prevent damage.

Summary of Contents for HDF 1X2

Page 1: ...1X2...

Page 2: ...g the Height of the Equipment 10 6 3 Securing the Equipment 10 6 4 Connection of the main manifolds inlet outlet and drainage 10 7 Control Unit Connection 10 8 Operation Instructions 10 8 1 Before Sta...

Page 3: ...s only use all necessary security and accident prevention methods to guarantee your security The improper use of the equipment may cause injury to people damage to property or the environment Improper...

Page 4: ...the instructions described in this manual Do not open the filter clamp when the equipment is pressurized it could cause serious injury to people the equipment or to the surrounding area Do use adequa...

Page 5: ...DF Disc Filters systems are subject to strict quality control tests and are manufactured under a production process which complies with the requirements of ISO 9001 2000 Rain Bird is committed to the...

Page 6: ...s responsible for collecting the filtered water and carrying to the exterior Rain Bird HDF 1X2 Disc Filters consists of a filtering element comprised of grooved discs that allows the retention of part...

Page 7: ...exerted by the spring on the discs stack generating a decompression due to the piston displacement raising The release of the discs creates rotation due to the tangential projection of the water comin...

Page 8: ...pment Serial number Max Pressure Year of Manufacturing Manufacturer Model Max Temperature 5 1 Assembly Part Identification COMPONENTS N DESCRIPTION 1 RAIN BIRD HDF DISC FILTER 2 INLET MANIFOLD GROOVED...

Page 9: ...E 14 15 16 13 10 11 12 7 N DESCRIPTION CHECK VALVES WITH ACCESORIES SET OF PISTON GASKETS SPRINGS MAINTENANCE KIT FILTERING ELEMENT O RING FRAME FRAME O RING PISTON GASKET 10 PISTON SPRING 1 1 11 PIST...

Page 10: ...ent dimensions the shoulders height should be adjusted so that the upper part of the drainage manifold is placed at a distance of 33 2 843 mm from the ground The separation between the shoulders shoul...

Page 11: ...inage manifold has a PVC grooved coupling from factory that glues to a 3 PVC pipe Connect the inlet outlet and drainage manifolds with its corresponding connections LEVEL AND SECURE TO THE GROUND TO A...

Page 12: ...P1 High Presure L1 E1 E1 T PRESSURE T PRESSURE The microtubes and unions are labelled according to the following nomenclature 12 7 CONTROL UNIT CONNECTION P1 and P2 are the pressure in the inlet and o...

Page 13: ...cated in the equipment technical data before starting up Do not operate outside of the recommended working conditions Equipment Pressure Make sure that the filter is depressurized before opening it Ma...

Page 14: ...their installation DAILY ACTION 1 Visual inspection of the equipment 2 Check for leakage in the equipment 3 Check the Operation Conditions pressure temperature flow rate PH 4 Evaluation of the equipm...

Page 15: ...lean only the discs in an acid solution If an acid solution is used to clean the discs use the adequate protection clothes glasses gloves face shield Consult the Safety Sheet of the product used Do no...

Page 16: ...ws manually and then use the wrench 5 Lubricate the base of the filter element O ring with a product chemically compatible with the material of the filter Insert the filtering element pushing carefull...

Page 17: ...II Apply grease to the coupling joint III Assemble the coupling 17 B Checking the Intake Filters I Disconnect P1 and P2 micro tubes II Remove the intake filters on the inlet and outlet manifolds with...

Page 18: ...ve any doubt contact your distributor WATER IN THE DRAINAGE MANIFOLD CONTROLLER FILTRATION PROCESS INSPECT EACH OF THE COMMAND MICROTUBES WHICH FEED THE HYDRAULIC VALVES CHAMBERS CHECK THE CORRESPONDI...

Page 19: ...ime of each station from the PROBLEM WITH THE DIFFERENTIAL PRESSURE GAUGE CHECK THE REGULATED VALUE IN THE DIFFERENTIAL PRESSURE GAUGE See section Differential Pressure Gauge Delay from the Control Un...

Page 20: ...ases or chemicals unless these materials and their concentrations are specified in the Rain Bird quotation 6 Electrical supply voltages above or below those specified for correct Filtration Products o...

Page 21: ...oration Tel 520 741 6100 Fax 520 741 6191 E mail Filters Rain Bird com http www RainBird com Request your spares to RAIN BIRD DISC FILTER ASSY DISC Series User s Manual 2013 00 21 4 2 Identification o...

Reviews: