OPERATION OF MULTIRAE PLUS
2 - 15
12) The
Communicate with PC?
menu allows the user to
upload data from the MultiRAE PLUS to a Personal
Computer (PC) or download configuration information
from a PC to the MultiRAE PLUS. Press the
[Y/+]
key
and the LCD displays the message “Monitor will pause,
OK?” to remind the users that during PC communication,
there will be no real time monitoring of the gas
concentration. Press
[Y/+]
to proceed and the monitor
enters the communication standby mode. The LCD then
displays “Ready...” Connect the monitor to the serial
port of a PC. The monitor is then ready to receive any
command from a PC (see Section 5 for details on
communications between the MultiRAE PLUS and a
PC).
Note: When the monitor is in communication
standby mode, it stops monitoring the gas
concentration and stops the datalogging.
Datalogging must be manually restarted when
exiting the communication standby mode, unless it
is in automatic datalogging mode.
Displays in text mode:
The four displays are arranged in a “round robin” order:
Sensor name
PC comm?
Instantaneous
reading
Battery voltage