DMD20/20LBST Universal Satellite Modem
Maintenance and Troubleshooting
MN-DMD20-20LBST Revision 14
6–5
6.2.1.5
Drop and Insert Alarms
Alarm
Possible Cause
Multiframe Lock
The insert framer is not in sync.
CRC Lock
An Insert CRC Fault occurred. Valid in T1-ESF, PCM-30, or PCM-
30C Modes.
T1 Signaling
An Insert T1 Yellow Fault occurred. Valid in T1-ESF, T1D4, or SCL-
96 Modes.
E1 FAS (E1 Frame
Acquisition Sync)
An E1 FAS Fault occurred. Valid in PCM-30, or PCM-30C, PCM-31,
or PCM-31C Modes.
E1 MFAS (E1 Multi-Frame
Acquisition Sync)
An E1 MFAS Fault occurred. Valid in PCM-30, or PCM-30C, PCM-
31, or PCM-31C Modes.
6.2.1.6
Common Major Alarms
Alarm
Possible Cause
TERR FPGA CFG
Indicates an Interface Card FPGA configuration failure probably
caused by a missing, or wrong file.
CODEC FPGA CFG
Indicates Turbo Codec Card FPGA configuration failure probably
caused by a missing, or wrong file.
+1.5V RX SUPPLY
Displays the measured voltage of the 1.5 Volt Rx power bus located
inside the modem.
+1.5V TX SUPPLY
Displays the measured voltage of the 1.5 Volt Tx power bus located
inside the modem.
+3.3V SUPPLY
Displays the measured voltage of the +3.3 Volt power bus located
inside the modem.
+5V SUPPLY
Displays the measured voltage of the +5 Volt power bus located
inside the modem.
+12V SUPPLY
Displays the measured voltage of the +12 Volt power bus
located inside the modem.
+20V SUPPLY
Displays the measured voltage of the +20 Volt power bus
located inside the modem.
EXT CLOCK ACT
Indicates that the External Clock is not active.
EXT REF ACT
Indicates no activity on the External Reference.
EXT REF LOCK
Indicates that the External Reference PLL is not locked.