DMD20/20LBST Universal Satellite Modem
Web Browser Setup Guide
MN-DMD20-20LBST Revision 14
F–5
F.2
Reset a User Account
Sometimes, it is necessary to reset a user account to the factory defaults. For example, a user
account may be locked because of too many incorrect password attempts. Release the lock by
resetting the user account. Then, set up the user account again.
To reset a User Account, do these steps:
1.
Select the User ID.
2.
Press the
down button.
3.
Press the
right button until you see USER RESET.
4.
Press ENTER to reset the User Account.
1.
USER 1: This will allow the operator to change the user name, assign the Access group,
authorized password for “USER 1”. Upon entering the following fields will be displayed:
a.
ACCESS GROUP: This will allow the assignment of “No Group”, “ADMIN”, “OPER”, or
GUEST to USER 1.
b.
AUTH PASSWORD: This will allow for the entry of the password for USER 1.
c.
USER RESET: Using this command will allow the factory defaults (as listed in the table
above) to be restored to USER 1. This can be used in the event that USER 1 is locked
out due to password restriction.
2.
USER 2: This has the same menu structure as USER 1.
3.
USER 3: This has the same menu structure as USER 1.
Radyne’s Web configuration allows for the support of 3 user profiles. These are configured
through the ‘PASSWORD/SETUP ACCESS section in the Web Browser.
F.3
Confirmation
You can enable or disable a confirmation prompt.
CONFIRMATION
ENABLED – causes a prompt that asks you to confirm or cancel changes.
DISABLED – no prompt occurs. Changes are effective immediately after you press
ENTER.