DMD20/20LBST Universal Satellite Modem
User Interfaces
MN-DMD20-20LBST Revision 14
4–10
option if the BUC does not support FSK or if the customer does
not want to utilize the FSK option.
CODAN:
Enables the FSK Communication link for CODAN BUCs only.
This feature enables the DMD20LBST to retrieve and display
certain BUC parameters on the front panel of the modem.
TERRASAT:
Enables the FSK communication link for Terrasat BUCs only.
This feature enables the DMD20LBST to retrieve and display
certain BUC parameters on the front panel of the modem.
AMPLUS:
Enables the FSK communication link for AMPLUS BUCs only.
This feature enables the DMD20LBST to retrieve and display
certain BUC parameters on the front panel of the modem.
If user enables the FSK and the BUC does not support FSK, the modem will display a
fault or if the user selects the incorrect manufacturers BUC, the unit will display a
fault.
BUC OUTPUT
{Enabled, Disabled}
Allows the user to enable or disable the BUC output
LO FREQ (MHz)
Allows the user to enter the Local Oscillator frequency of the
BUC LO in order for the uplink frequency to be displayed
correctly (refer to the BUC manufacturer’s specifications).
When utilizing BUC that supports FSK, the modem will display LO frequency as stated
by the BUC.
OSC SIDE BAND
{LOW SIDEBAND, HIGH SIDEBAND}
Allows the user to select the location of the BUC LO. The user
must enter the location of the BUC LO in order for the UPLINK
FREQUENCY to be displayed correctly. The BUC LO can be
either higher or lower in frequency than the BUC output
frequency. If the BUC LO is higher in frequency then the user
must enter HIGH SIDEBAND.
10 MHz BUC REF
{ENABLED, DISABLED}
Allows the user to enable or disable the 10 MHz BUC reference
clock.
BUC VOLTAGE
{ENABLED, DISABLED}
Allows the user to enable or disable the BUC supply voltage.
LOW ALARM THRSH
{0.00 Volts}
Allows user to select lower alarm limit/threshold for BUC voltage.
IMPORTANT
IMPORTANT