DMD20/20LBST Universal Satellite Modem
User Interfaces
MN-DMD20-20LBST Revision 14
4–13
RADYNE:
When configured for Radyne AUPC, the maximum
Transmit Power is the highest power setting that will be used
when the remote modem commands an increase of the Transmit
Power from the Local modem
NEARSIDE:
When configured for NEARSIDE AUPC the
maximum Transmit Power is the highest power setting that will
be used by the local modem when the Eb/No decreases below
the Eb/No target.
TARGET Eb/No
{4.0 to 16 dB}
This allows the user to set the desired E
b
/N
o
for the local
receiver.
RADYNE AUPC:
When configured for Radyne AUPC, this
setting is compared against the remote E
b
/N
o
and commands to
the local modem to increase or decrease the local transmit
power.
EF AUPC:
When configured for EF AUPC, this setting is
compared against the local received E
b
/N
o
and commands to the
remote modem to increase or decrease transmit power.
NEARSIDE:
When configured for NEARSIDE AUPC, this
setting is compared against the received E
b
/N
o
of the local
modem and commands to the local modem to increase or
decrease transmit power.
TRACKING RATE
{0.5 to 6.0}
Allows the user to set the rate at which the commands to
increase or decrease Transmit Power are sent. Each command
will result in a 0.5 dB increase or decrease in Transmit Power
from the remote transmitter. The tracking rate is adjustable from
0.5 dB per minute to 6.0 dB per minute in 0.5 dB steps.
(Only
available when EFAUPC is selected as the framing)
LOCAL CL ACTION
{HOLD, NOMINAL, MAXIMUM}
This allows the user to set the Remote Transmit Power Setting to
be used when the local modem receiver loses lock. The setting
can be 'HOLD' (no action taken), 'NOMINAL' (the nominal
Transmit Power Setting is used), and 'MAXIMUM' (the maximum
Transmit Power Setting is used).
(Only available when
EFAUPC is selected as the framing)
REMOTE CL ACTION
{HOLD, NOMINAL, MAXIMUM}
This allows the user to set the Local Transmit Power Setting to
be used when the remote modem receiver loses lock. The
setting can be 'HOLD' (no action taken), 'NOMINAL' (the nominal
Transmit Power Setting is used), and 'MAXIMUM' (the maximum
Transmit Power Setting is used).
REMOTE AUPC (menu)
The 'REMOTE AUPC CONFIGURATION' Menu contains the
remote configuration parameters for the AUPC Function.
Remote AUPC menus are only available when modem is
configured for EF AUPC