![RadiSys ATCA-4616 Reference Download Page 98](http://html.mh-extra.com/html/radisys/atca-4616/atca-4616_reference_780512098.webp)
B
IPMI Commands and Managed Sensors
98
33
+12V
Voltage
Threshold
12.00
LNR = 0.00
LC = 10.8
LNC = 11.4
UNC = 12.6
UC = 13.2
UNR = 13.8
34
+5V
Voltage
Threshold
5.00
LNR = 0.00
LC = 4.5
LNC = 4.75
UNC = 5.25
UC = 5.49
UNR = 5.74
35
+5V Standby
Voltage
Threshold
5.00
LNR = 0.00
LC = 4.5
LNC = 4.75
UNC = 5.25
UC = 5.49
UNR = 5.74
36
+3.3V IPMI
Voltage
Threshold
3.30
LNR = 0.00
LC = 2.97
LNC = 3.15
UNC = 3.47
UC = 3.64
UNR = 3.8
37
+3.3V Voltage
Threshold
3.30
LNR
=
0.00
LC = 2.97
LNC = 3.15
UNC = 3.47
UC = 3.64
UNR = 3.8
38
+1.8V
Voltage
Threshold
1.80
LNR = 0.00
LC = 1.62
LNC = 1.71
UNC = 1.89
UC = 1.98
UNR = 2.04
39
+1.8V FR
Voltage
Threshold
1.80
LNR = 0.00
LC = 1.62
LNC = 1.71
UNC = 1.89
UC = 1.98
UNR = 2.04
Table 38. ATCA-46xx IPMI Managed Sensors (continued)
Sensor
#
Name
Type
Reading
Type
Normal
Reading
Notes