B
IPMI Commands and Managed Sensors
97
13
ENET Link 1
Slot or
Connector
Digital
0 or 1
0 = E1_LINK* not asserted
1 = E1_LINK* asserted
14
ENET Link 2
Slot or
Connector
Digital
0 or 1
0 = E2_LINK* not asserted
1 = E2_LINK* asserted
15
ENET Link 3
Slot or
Connector
Digital
0 or 1
0 = E3_LINK* not asserted
1 = E3_LINK* asserted
16
ENET Link 4
Slot or
Connector
Digital
0 or 1
0 = E4_LINK* not asserted
1 = E4_LINK* asserted
17
ENET Link 5
Slot or
Connector
Digital
0 or 1
0 = E5_LINK* not asserted
1 = E5_LINK* asserted
18
-48V Absent A
Power Supply
Digital
0 or 1
0 = Power Supply A. Presence detected
1 = Power Supply A. Failure detected
19
-48V Absent B
Power Supply
Digital
0 or 1
0 = Power Supply B. Presence detected
1 = Power Supply B. Failure detected
20
-48V Fuse Fault
Power Supply
Digital
0 or 1
0 = Both A & B fuses OK and both supplies detected
1 = Either A or B fuse blown or only single supply detected
21
System PwrFail
Power Supply
Digital
0 or 1
0 = Power is good
1 = Power fail detected
22
+12V RTM PwrFail
Power Supply
Digital
0 or 1
0 = De-Asserted
1 = Asserted
23
+3.3V RTM Fail
Power Supply
Digital
0 or 1
0 = De-Asserted
1 = Asserted
24
RTM PwrFault
Power Supply
Digital
0 or 1
0 = RTM PwrFault not asserted
1 = RTM PwrFault asserted
25
RTM PCIe PwrEn
Power Supply
Digital
0 or 1
0 = RTM PCIe PwrEn not asserted
1 = RTM PCIe PwrEn asserted
26
RTM PCIe2 PwrEn
Power Supply
Digital
0 or 1
0 = RTM PCIe2 PwrEn not asserted
1 = RTM PCIe2 PwrEn asserted
27
CPU0 ThermTrip
Processor
Digital
0 or 1
0 = CPU ThermTrip not asserted
1 = CPU ThermTrip asserted
28
CPU1 ThermTrip
Processor
Digital
0 or 1
0 = CPU ThermTrip not asserted
1 = CPU ThermTrip asserted
29
CPU MCERR
Processor
Digital
0 or 1
0 = CPU MCERR not asserted
1 = CPU MCERR asserted
30
CPU0 ProcHot
Processor
Digital
0 or 1
0 = CPU ProHot not asserted
1 = CPU ProHot asserted
31
CPU1 ProcHot
Processor
Digital
0 or 1
0 = CPU ProHot not asserted
1 = CPU ProHot asserted
32
CPU IERR
Processor
Digital
0 or 1
0 = CPU IERR not asserted
1 = CPU IERR asserted
Table 38. ATCA-46xx IPMI Managed Sensors (continued)
Sensor
#
Name
Type
Reading
Type
Normal
Reading
Notes