In
OFF
or
Extinguishing
state you can reset an Alarm visualization by pushing
(+)
or
(-)
button,
but if the alarm were still there you would visualize it again
.
8.1.2 Led
1.
Led Auger :
It is ON when the Auger Output is ON.
2.
Led Fan :
It is ON when the Fan1 Output is ON.
3.
Led Pump :
It is ON when the Pump Output is ON, it blinks when the Pump is switched
OFF by the Room Thermostat input.
4.
Led Boiler:
It is ON when the Water Temperature is under the value
BOILER-TH[A03]
–
ModulationDelta[A05]
.It blinks when the water temperature is over that value.It is
OFF when the temperature is over the
BOILER-TH[A03]
.
5.
Led Exhaust :
This Led is ON when exhaust temperature is over the
TH-ON [F18]
,It
blinks during the pre-extinguishing phase.
6.
Led Pellet :
The Led is ON in Pellet Modality Blinking during
Pre-Extinguishing-TIME
t06
7.
Led Ign.Resistance :
This Led is ON when the Ignition Resistance Output is ON
8.
Led Wood:
The Led is ON in Wood Modality
9.
Led Recipe T1 :
This Led is ON if Recipe1 is selected.
10.
Led Recipe T2 :
This Led is ON if Recipe2 is selected.
11.
Led Chrono :
This Led is ON when the Chrono input contact is closed.
8.1.3 Display
Display\Temperature\State\Alarms:
The 4 digit Display visualizes water temperature, the functioning State of the system and
eventual alarms:
Display Discription
Display
Discription
OFF state
Modulation
Check up
Stand by
Ignition
Safety
Stabilization
Extinguishing
Recover ignition
System off with alarms
If there are alarms the Display will show alternatively ALt / ErrorCode:
Display Discription
Display
Discription
Manually rearmed Safety
Thermostat
contact is open
Accidental Extinguishing
Over Boiler Temperature
Probe reading out of range
Failed Ignition