17
9.
The concealing plate bracket assembly (408 77) is provided with a foam seal
on its rear face, which mates with the wall surface and reduces the possibility
of water penetration into the recess. Should the wall surface or tiling be uneven,
this seal will not be fully effective and should be assisted/substituted by silicone
sealant.
Align and secure concealing plate bracket assembly to mounting bracket with
2 each of 30 mm panhead stainless steel screws (616 52), washers (642 10) and
nuts (626 26) provided.
10.
Remove protective film from concealing plate (408 76), and align into position
with bracket. Press firmly at each corner to secure. Refit temperature knob.
Refer to
COMMISSIONING
.
Installation - Rada 215-t3 bc
- thin panel
The Rada 215-t3 bc incorporates a mounting bracket, enabling the valve to be installed
through a laminated panel or shower cubicle.
The bracket must be mounted to the rear face of panels of 2-15 mm finished thickness
(see below for thicker panels).
The rear clearance requirement is 50 mm
1.
Cut a hole in the panel measuring 180 x 117 mm
2.
Drill 2 fixing holes of 4 mm diameter at 212 mm centres in the positions shown on
Figure 4
and
Figure 5
.
3.
Follow previous instructions
1-2
for
wall recess installation
.
4.
Fit mounting bracket (407 88) to valve base using 2 screws (615 39) supplied. If
access is available it may be preferable to make the initial valve/pipework
connections prior to securing the mixing valve to the panel.
5
.
Mount the mixing valve securely onto rear of panel (see
Figure 5
), with 2 each of
30 mm panhead stainless steel screws (616 52), washers (642 10) and nuts
(626 26) provided.
6.
Important:
Flush through the hot and cold supplies thoroughly before
connection to mixing valve
.
7.
Connect inlet and outlet pipework, checking that the hot and cold supplies have
been piped to the correct inlets, and check all connections are watertight.
8.
Follow previous instructions
7-10
for
wall recess installation
.
Refer to
COMMISSIONING
.