background image

for non-sealed floor construction

Model

Year built:

4937.2

from  01/2010

en_INT

Advantix plug-in drain

Instructions for Use

Summary of Contents for Advantix 4937.2

Page 1: ...for non sealed floor construction Model Year built 4937 2 from 01 2010 en_INT Advantix plug in drain Instructions for Use ...

Page 2: ...Advantix plug in drain 2 from 14 ...

Page 3: ...6 2 2 2 Media 6 2 2 3 Drainage capacity 6 2 3 Product description 7 2 3 1 Overview 7 2 3 2 Technical data 7 2 4 Information for use 8 2 4 1 Installation variations 8 3 Handling 9 3 1 Assembly information 9 3 1 1 Important note 9 3 1 2 Installation dimensions 9 3 2 Assembly 10 3 2 1 Connecting the drain 10 3 3 Care 12 3 3 1 Care tips 12 3 3 2 Cleaning the drain 13 3 4 Disposal 14 Table of contents ...

Page 4: ...does not extend to possible operating instructions The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use 1 2 Labelling of notes Warning and advisory texts are set aside from the remainder of the text and are labelled with the relevant pictographs DANGER This symbol warns against possible life threatening injury WAR...

Page 5: ...or in Germany e g DIN DVGW Some passages in the text may refer to technical codes in Europe Germany These should serve as recommendations in the absence of corresponding national regulations The relevant national laws stand ards regulations directives and other technical provisions take priority over the German European directives specified in this manual The information herein is not binding for ...

Page 6: ...e slabs are laid directly onto the soil or cellars in which small amounts of wastewater occur at irregular intervals Technical information see Ä Chapter 2 3 2 Technical data on page 7 2 2 2 Media The drain is intended for draining of household type wastewater in con stant operation see Ä Regulations from section Media on page 6 n The short term temperature of the wastewater may reach up to 95 C Th...

Page 7: ...f 4 stainless steel frame 5 drain casing with multiple lip seal 2 3 2 Technical data Nominal width DN drain socket 100 Drainage capacity Ä Chapter 2 2 3 Drainage capacity on page 6 Dimensions and installa tion height Ä Chapter 3 1 2 Installation dimen sions on page 9 Load class K 300 kg Product information Advantix plug in drain 7 from 14 ...

Page 8: ... 1 Installation variations The drain is placed into a pipe nominal width DN 100 The drain itself is integrated into the floor at the height of the grate Fig 2 Mounting example Product information Advantix plug in drain 8 from 14 ...

Page 9: ...rain corresponds with the planned floor construction n Ensure that the required connection line is installed with the neces sary incline to the planned installation location During assembly n Observe installation dimensions 3 1 2 Installation dimensions Fig 3 Dimensional drawing As at least three sealing lips must be inside the pipe the following installation heights occur Fig 4 Minimum installati...

Page 10: ... drainpipe At least 3 sealing lips should seal the drain in the pipe INFO If the drain is used in a pipe with a coupling the sealing lips cannot seal inside the coupling Therefore a pipe section must be inserted into the coupling beforehand Insert stainless steel grate Mounting the drain Handling Advantix plug in drain 10 from 14 ...

Page 11: ...Apply protective sticker Lay tiles Close the gap between grate and tiles with silicone Remove protective sticker Handling Advantix plug in drain 11 from 14 ...

Page 12: ...cale on the grate and frame Under no circum stances should scouring agent or scratching objects be used Strong stains even around the drain unit and the siphon can be removed using typical household cleaner It should be noted that the cleaning agent should be rinsed off after the prescribed soaking time There should be no residue on the components Handling Advantix plug in drain 12 from 14 ...

Page 13: ...rain We recommend using a mild cleaning agent and a washing up brush for cleaning Remove and clean grate Remove and clean odour trap Clean drain Replace odour trap Re insert grate Handling Advantix plug in drain 13 from 14 ...

Page 14: ...sposal Separate the product and packaging materials e g paper metal plastic or non ferrous metals and dispose of in accordance with valid national legal requirements Handling Advantix plug in drain 14 from 14 ...