Default = BCC
According to the DF1 specification, either BCC or CRC for Block control mode (data integrity) can
be used.
•
Broadcast
According to the DF1 specification, packets for the destination address 0xFF are considered
broadcasts. Hence when Broadcast is On, packets with this destination are handled as broadcasts.
Address translation
Table
Mask
•
Advanced parameters
○
ACK Locally
List box: Off, On
Default = On
If "
On
", ACK frames (0x1006)are not transferred over-the-air.
When the RipEX receives a data frame from the connected device, it generates the ACK frame
(0x1006) locally. When the RipEX receives the data frame from the Radio channel, it sends the
frame to the connected device and waits for the ACK. If the ACK is not received within 1 sec.
timeout, RipEX sends ENQ (0x1005). ENQ and ACK are not generated for broadcast packets.
Profibus
RipEX supports Profibus DP (Process Field Bus, Decentralized Periphery) the widest-spread version
of Profibus. The Profibus protocol configuration uses all parameters described in
Common parameters.
Mode of Connected device
Master
Broadcast
Address translation
Table
Mask
Slave
Broadcast accept
C24
C24 is a serial polling-type communication protocol used in Master-Slave applications.
When a RipEX radio network runs in the Router mode, multiple C24 Masters can be used within one
Radio network and one Slave can be polled by more than one Master.
Underlined parameters are described in
Common parameters
.
Mode of Connected device
Master
Address translation
Table
99
© RACOM s.r.o. – RipEX Radio modem & Router
Advanced Configuration