background image

STEALTH-IN-1114

Keeps lights on for 1-8 hours after dusk. Sensor then reverts to Automatic 

Mode until dawn. If you set the Evening Timer Mode during daylight, the 

sensor will be prepared to turn on at dusk and remain on for the number of 

hours you set. When the sensor is in “Ready for Evening Timer  

Mode”, the middle LED will  

blink 3 times, pause and repeat. 

Set the Evening Timer by  

flipping the switch that operates 

the sensor 3 times within 

3 seconds (off-onoff-of off-on).

Sensor Modes

AUTOMATIC MODE

Lights will turn on when there 

is movement within the de-

tection zone after dusk.

EVENING TIMER MODE

“On Guard Auto Mode”  

LEDs scan continuously back and forth

“Ready for Evening Timer Mode”  

Middle LED blinks

TEST MODE 

The Test Mode will allow you to test the sensor during the day regardless of 

the photocell setting.

 

To enter Test Mode, turn time setting to 5 sec on the 

unit. Turn power off for 10 secs then back on.  There is a 30 second warm-up 

period, then the Test Mode starts. During the warm-up, the lights stay on 

continiously and LEDs are off.  During Test Mode the LEDs remain off.  The 

sensor will stay in Test Mode until the detection zone is vacated for one 

minute. 

 

During the Test Period, the sensor will keep lights on for  

5 seconds each time it detects movement in its detection zone. Perform the 

walk test and make any adjustments needed.  Vacate the detection zone for 

one minunte to end Test Mode. Scanning LEDs will appear when test mode 

ends. Set back to desired time setting after testing complete.

MANUAL OVERRIDE MODE

The STL360 has a “protected” Manual Override that requires a double-flip of 

the light switch so momentary power problems do not interfere with normal 

sensor operation.

By flipping the switch that operates the sensor twice (off-on-off-on) within 

2 seconds you will override the sensor to keep lights on continuously until 

dawn.

If you set the Manual Override Mode during daylight, the sensor will be 

prepared to turn on at dusk and remain on until dawn. This is a handy feature 

if you leave home for the day and you want the lights on to greet you when 

you return. When the sensor is in “ Ready for Manual Override Mode” the 

middle LED will be on.

TO RESUME AUTOMATIC MODE

Switch OFF the power for at least 10 seconds, then turn it ON again. Sensor 

will reset to Automatic Mode after completing the warm-up period. 

 

DAYTIME (24-HOUR) OPERATION OF MANUAL OVERRIDE

If you set Manual Override while set to 24 hour operation, lights will come on 

and remain on continously.

Lights will not turn off at dawn.

“Ready for Manual Override Mode” 

Middle LED on

13

14

TIME

1           8 HRS

5 SECS          12 MINS

–         +

EVENING

  TIMER

SENS

Summary of Contents for FFLED18

Page 1: ...or silicone sealant 2 Secure the LED Flood to a 1 2 NPS hole in a junction box or landscape post 3 Plug all unused holes and seal threads with silicone 4 The swivel arm on the LED Flood allows 140 150...

Page 2: ...e at the fixture is correct Refer to wiring directions 2 Is the fixture grounded properly 3 Is the photocell if used functioning properly Note These instructions do not cover all details or variations...

Page 3: ...volts Cautions TURN OFF ALL POWER AT CIRCUIT BREAKER FUSE PANEL Read entire Installation Manual before proceeding All wiring should comply with local electrical codes and requires a qualified electri...

Page 4: ...es Since the lights are on only when needed and the sensor uses only one watt The Stealth is extremely energy efficient Can outdoor lights still be turned on with the light switch Yes STL360 can be co...

Page 5: ...st be located below and as far away as possible from its lights The best location is where the sensor can see all paths of movement The sensor may be wall or soffit mounted As distance from the sensor...

Page 6: ...f the detection zone may be high in the air over people s heads Check that movement is not directly towards sensor Sensor will see movement ACROSS its pattern move quickly Check that move ment far awa...

Page 7: ...ure O Ring gasket is on the screw to attach CU4 EZ Plate to the box 8 Insert plastic Finishing Cap in the center of the CU4 EZ Plate for a weath erproof seal 9 Use silicone sealant around plate and al...

Page 8: ...shown in wiring diagram 9 Twist on wire nuts Secure with electrical tape 10 Make sure all unused openings in CU4 EZ Plate are closed with plugs provided 11 Use silicone sealant around plate and all o...

Page 9: ...nd then off at bedtime To activate the EVENING TIMER flip the wall switch controlling the sensor three times slowly off on off on off on within 3 seconds If you activate the EVENING TIMER during dayti...

Page 10: ...keep lights on for 5 seconds each time it detects movement in its detection zone Perform the walk test and make any adjustments needed Vacate the detection zone for one minunte to end Test Mode Scann...

Page 11: ...is not triggering sensor Make sure the sensor is below and as far as possible away from lights Easy Installation Product Help Tech Help Line Call our experts 888 RAB 1000 2014 RAB LIGHTING Inc Northv...

Page 12: ...ops 8 Moths can be attracted to the lights and fly close to the sensor causing triggering Reducing the sensitivity may help 9 Check Solutions 3 4 5 6 7 and 8 under Lights Do Not Turn OFF 1 Check that...

Page 13: ...itive Less sensitive TIME 1 8 HRS 5 SECS 12 MINS EVENING TIMER SENS Technical Tips Lights Turn Off too quickly WRONG OK Technical Tips Range Appears Limited 1 Check that the sensor is level from side...

Page 14: ...r who purchased the product directly from RAB and from no other source b if the product has been installed the entire installation was performed by a licensed electrician or under the supervision of a...