background image

Installation Manual

STL360HBW

The STEALTH 360 is the most reliable 

and technically advanced motion- 

activated light control ever  

produced. This technical manual is 

written for electrical professionals 

who wish to maximize the  

performance and reliability of this 

superb sensor.

RAB welcomes your questions or 

comments. 

Please call 888 722 1000 or email 

[email protected].

Thank you for purchasing a RAB sensor.

STL360H

Specifications:

Switching Capacity: 

8 amps 

Voltage: 

  120 

volts 

Protection Pattern:  

180º forward 

 

 

 

360º below and to the sides 

Time Adjustment:   

5 seconds to 12 minutes 

Power Consumption: 

1 watt 

Surge protection:   

6000 volts

Cautions:

TURN OFF ALL POWER AT CIRCUIT BREAKER/FUSE PANEL 

 

Read entire Installation Manual before proceeding.

 

All wiring should comply with local electrical codes and  
requires a qualified electrician.

 

The total lighting load connected to STL360 must not exceed (1000 watts 
incandescent, 250 watts fluorescent). To switch more wattage, an electri-
cian can install a relay.

 

Line Carrier Remote Control Systems such as X-10, Leviton or Radio Shack 
are incompatible with sensors and may cause false activations.

 

Do not install sensors on a circuit that feeds motor loads such as kitchen 
appliances, HVAC equipment, washer/dryer, or garage door openers.

 

Sensor functions best when the direction of expected  
movement is across its detection pattern, not towards the sensor. 

Mount 6’-10’ high for optimum range and detection.

STL3FFLED18

Summary of Contents for FFLED18

Page 1: ...or silicone sealant 2 Secure the LED Flood to a 1 2 NPS hole in a junction box or landscape post 3 Plug all unused holes and seal threads with silicone 4 The swivel arm on the LED Flood allows 140 150...

Page 2: ...e at the fixture is correct Refer to wiring directions 2 Is the fixture grounded properly 3 Is the photocell if used functioning properly Note These instructions do not cover all details or variations...

Page 3: ...volts Cautions TURN OFF ALL POWER AT CIRCUIT BREAKER FUSE PANEL Read entire Installation Manual before proceeding All wiring should comply with local electrical codes and requires a qualified electri...

Page 4: ...es Since the lights are on only when needed and the sensor uses only one watt The Stealth is extremely energy efficient Can outdoor lights still be turned on with the light switch Yes STL360 can be co...

Page 5: ...st be located below and as far away as possible from its lights The best location is where the sensor can see all paths of movement The sensor may be wall or soffit mounted As distance from the sensor...

Page 6: ...f the detection zone may be high in the air over people s heads Check that movement is not directly towards sensor Sensor will see movement ACROSS its pattern move quickly Check that move ment far awa...

Page 7: ...ure O Ring gasket is on the screw to attach CU4 EZ Plate to the box 8 Insert plastic Finishing Cap in the center of the CU4 EZ Plate for a weath erproof seal 9 Use silicone sealant around plate and al...

Page 8: ...shown in wiring diagram 9 Twist on wire nuts Secure with electrical tape 10 Make sure all unused openings in CU4 EZ Plate are closed with plugs provided 11 Use silicone sealant around plate and all o...

Page 9: ...nd then off at bedtime To activate the EVENING TIMER flip the wall switch controlling the sensor three times slowly off on off on off on within 3 seconds If you activate the EVENING TIMER during dayti...

Page 10: ...keep lights on for 5 seconds each time it detects movement in its detection zone Perform the walk test and make any adjustments needed Vacate the detection zone for one minunte to end Test Mode Scann...

Page 11: ...is not triggering sensor Make sure the sensor is below and as far as possible away from lights Easy Installation Product Help Tech Help Line Call our experts 888 RAB 1000 2014 RAB LIGHTING Inc Northv...

Page 12: ...ops 8 Moths can be attracted to the lights and fly close to the sensor causing triggering Reducing the sensitivity may help 9 Check Solutions 3 4 5 6 7 and 8 under Lights Do Not Turn OFF 1 Check that...

Page 13: ...itive Less sensitive TIME 1 8 HRS 5 SECS 12 MINS EVENING TIMER SENS Technical Tips Lights Turn Off too quickly WRONG OK Technical Tips Range Appears Limited 1 Check that the sensor is level from side...

Page 14: ...r who purchased the product directly from RAB and from no other source b if the product has been installed the entire installation was performed by a licensed electrician or under the supervision of a...

Reviews: