STEALTH-IN-1114

 

To install a STL360 Sensor with separately purchased floodlights, 

start at #1 

 

To install STL360 Pre-wired Floodlight Kits, see page 7.

 

1. 

Screw the threaded arms of each floodlight into the RAB CU4 EZ Plate.

(See diagram on page 7) 

2. 

Screw the threaded arm of the sensor into the bottom hole of the EZ 

Plate. Sensor should be below and as far away from the floodlights as 

possible. 

3. 

Attach the Universal Mounting bar with the screws provided to the 

junction box. If you are attaching your STL360 kit to a surface mount 

weatherproof box, you must use the metal mounting plate with gasket. 

4. 

Use the “S” shaped Hands Free Hanging Hook to hold the EZ Plate  

during wiring. 

5. 

Bring power leads and sensor kit leads through holes in gasket into 

junction box. 

6. 

Attach ground wire(s) to junction box grounding screw. 

7. 

Position CU4 EZ Plate and metal surface plate with  

gasket (required for mounting on surface junction boxes) (see pg #7). 

8. 

Strip 1/2” of insulation from all leads.  

Connect as shown in wiring diagram. 

9. 

Twist on wire nuts.  

Secure with electrical tape. 

10. 

Make sure all unused openings  

in CU4 EZ Plate are closed  

with plugs (provided). 

11. 

Use silicone sealant around plate and all openings to ensure a weather 

proof seal.  Seal all unsued conduit entries on surface junction box. 

12. 

Screw in light bulbs. Turn on power.  

13. 

Conduct walk test to adjust sensor response (see page 15).

Multiple Sensors

STL360 Assembly and Wiring

Multiple sensors may be wired together, but doing this will make problems 

difficult to troubleshoot. Single sensors that control their own lights will give 

a more accurate location of movement and trouble-free operation.

Multiple Fixtures 

Multiple fixtures may be wired 

to a single sensor.

To handle loads greater than 

1000 watts, a qualified  

electrician should install a relay.

Power Quality 

It is not recommended to install sensors on a circuit that also feeds motor 

loads such as HVAC equipment, kitchen appliances, or garage door openers. 

The Stealth circuit is surge and transient protected to IEC specifications.  

However, if voltage varies significantly from 120 volts, the sensor may  

malfunction. This may occur on circuits with motor loads. 

9

10

Summary of Contents for FFLED18

Page 1: ...or silicone sealant 2 Secure the LED Flood to a 1 2 NPS hole in a junction box or landscape post 3 Plug all unused holes and seal threads with silicone 4 The swivel arm on the LED Flood allows 140 150...

Page 2: ...e at the fixture is correct Refer to wiring directions 2 Is the fixture grounded properly 3 Is the photocell if used functioning properly Note These instructions do not cover all details or variations...

Page 3: ...volts Cautions TURN OFF ALL POWER AT CIRCUIT BREAKER FUSE PANEL Read entire Installation Manual before proceeding All wiring should comply with local electrical codes and requires a qualified electri...

Page 4: ...es Since the lights are on only when needed and the sensor uses only one watt The Stealth is extremely energy efficient Can outdoor lights still be turned on with the light switch Yes STL360 can be co...

Page 5: ...st be located below and as far away as possible from its lights The best location is where the sensor can see all paths of movement The sensor may be wall or soffit mounted As distance from the sensor...

Page 6: ...f the detection zone may be high in the air over people s heads Check that movement is not directly towards sensor Sensor will see movement ACROSS its pattern move quickly Check that move ment far awa...

Page 7: ...ure O Ring gasket is on the screw to attach CU4 EZ Plate to the box 8 Insert plastic Finishing Cap in the center of the CU4 EZ Plate for a weath erproof seal 9 Use silicone sealant around plate and al...

Page 8: ...shown in wiring diagram 9 Twist on wire nuts Secure with electrical tape 10 Make sure all unused openings in CU4 EZ Plate are closed with plugs provided 11 Use silicone sealant around plate and all o...

Page 9: ...nd then off at bedtime To activate the EVENING TIMER flip the wall switch controlling the sensor three times slowly off on off on off on within 3 seconds If you activate the EVENING TIMER during dayti...

Page 10: ...keep lights on for 5 seconds each time it detects movement in its detection zone Perform the walk test and make any adjustments needed Vacate the detection zone for one minunte to end Test Mode Scann...

Page 11: ...is not triggering sensor Make sure the sensor is below and as far as possible away from lights Easy Installation Product Help Tech Help Line Call our experts 888 RAB 1000 2014 RAB LIGHTING Inc Northv...

Page 12: ...ops 8 Moths can be attracted to the lights and fly close to the sensor causing triggering Reducing the sensitivity may help 9 Check Solutions 3 4 5 6 7 and 8 under Lights Do Not Turn OFF 1 Check that...

Page 13: ...itive Less sensitive TIME 1 8 HRS 5 SECS 12 MINS EVENING TIMER SENS Technical Tips Lights Turn Off too quickly WRONG OK Technical Tips Range Appears Limited 1 Check that the sensor is level from side...

Page 14: ...r who purchased the product directly from RAB and from no other source b if the product has been installed the entire installation was performed by a licensed electrician or under the supervision of a...

Reviews: