background image

STEALTH-IN-1114

Locations Near Roads

Cars and passing traffic may activate the sensor if it is aimed at the road. 

To Improve Performance in Difficult Locations:

• 

Reduce sensitivity by turning the SENS knob counterclockwise, 

 

 

 

• 

Mask lens in the direction of  

the traffic using the lens mask 

provided or opaque tape.  

(Lens Mask can be broken  

along lines to desired size) 

• 

Make sure that sensor is not aimed 

 at traffic. The sensor should  

be aimed down so that the  

maximum range of the sensor  

ends at least 20’ from the road.  

This will avoid detection of  

passing trucks and cars, or the  

air currents they create.

TIME

1           8 HRS

5 SECS          12 MINS

–         +

EVENING

  TIMER

SENS

Mount Level 

The sensor should be mounted level 

from side to side and pointed at the 

area where you desire coverage. If 

tilted, part of the detection zone 

may be high in the air over people’s 

heads. 

Check that movement is not directly 

towards sensor. Sensor will see 

movement ACROSS its pattern 

move quickly. Check that move-

ment far away and directly towards 

sensor is not entirely within one 

zone. To fix, change the sensor 

angle or location.

 

If the sensor is located over a 

pathway so all movement is directly 

toward it, range may appear limited. 

“Micro Adjust” sensor by moving 

sideways 1/4” or so, which may  

reposition the zones enough to  

allow earlier detection. 

 

 

Choose a Protected Location

Mount sensor in protected area. 

The more protected the mounting 

location, the less chance of lights 

turning on occasionally during 

rain, snow and windstorms.  This 

could happen because the sensor 

is detecting dramatic changes in 

temperature.

Locate for Movement Across Pattern

Choosing a Location

20’ 

safety 

zone

Lens Mask 

(included)

WRONG

OK!

OK!

More sensitive

Less  
sensitive

Better detection after

“micro adjustment”

WRONG

OK!

5

6

Summary of Contents for FFLED18

Page 1: ...or silicone sealant 2 Secure the LED Flood to a 1 2 NPS hole in a junction box or landscape post 3 Plug all unused holes and seal threads with silicone 4 The swivel arm on the LED Flood allows 140 150...

Page 2: ...e at the fixture is correct Refer to wiring directions 2 Is the fixture grounded properly 3 Is the photocell if used functioning properly Note These instructions do not cover all details or variations...

Page 3: ...volts Cautions TURN OFF ALL POWER AT CIRCUIT BREAKER FUSE PANEL Read entire Installation Manual before proceeding All wiring should comply with local electrical codes and requires a qualified electri...

Page 4: ...es Since the lights are on only when needed and the sensor uses only one watt The Stealth is extremely energy efficient Can outdoor lights still be turned on with the light switch Yes STL360 can be co...

Page 5: ...st be located below and as far away as possible from its lights The best location is where the sensor can see all paths of movement The sensor may be wall or soffit mounted As distance from the sensor...

Page 6: ...f the detection zone may be high in the air over people s heads Check that movement is not directly towards sensor Sensor will see movement ACROSS its pattern move quickly Check that move ment far awa...

Page 7: ...ure O Ring gasket is on the screw to attach CU4 EZ Plate to the box 8 Insert plastic Finishing Cap in the center of the CU4 EZ Plate for a weath erproof seal 9 Use silicone sealant around plate and al...

Page 8: ...shown in wiring diagram 9 Twist on wire nuts Secure with electrical tape 10 Make sure all unused openings in CU4 EZ Plate are closed with plugs provided 11 Use silicone sealant around plate and all o...

Page 9: ...nd then off at bedtime To activate the EVENING TIMER flip the wall switch controlling the sensor three times slowly off on off on off on within 3 seconds If you activate the EVENING TIMER during dayti...

Page 10: ...keep lights on for 5 seconds each time it detects movement in its detection zone Perform the walk test and make any adjustments needed Vacate the detection zone for one minunte to end Test Mode Scann...

Page 11: ...is not triggering sensor Make sure the sensor is below and as far as possible away from lights Easy Installation Product Help Tech Help Line Call our experts 888 RAB 1000 2014 RAB LIGHTING Inc Northv...

Page 12: ...ops 8 Moths can be attracted to the lights and fly close to the sensor causing triggering Reducing the sensitivity may help 9 Check Solutions 3 4 5 6 7 and 8 under Lights Do Not Turn OFF 1 Check that...

Page 13: ...itive Less sensitive TIME 1 8 HRS 5 SECS 12 MINS EVENING TIMER SENS Technical Tips Lights Turn Off too quickly WRONG OK Technical Tips Range Appears Limited 1 Check that the sensor is level from side...

Page 14: ...r who purchased the product directly from RAB and from no other source b if the product has been installed the entire installation was performed by a licensed electrician or under the supervision of a...

Reviews: