background image

USER MANUAL

Version:1.0

LT-1220

Summary of Contents for LT-1220

Page 1: ...USER MANUAL Version 1 0 LT 1220 ...

Page 2: ......

Page 3: ... specification 15 10 1 Electrical paramters 15 10 2 10 3 4 2Installing the Clamps 3 4 3 Power supply connection and cut off 4 4 4 Power Connection 4 4 5 DMX 512 connection connection between fixtures 4 15 Channel Characteristics 15 10 4 Menu Function 15 10 5 Light table 15 11 Electronic drawing 16 Description of the device 6 Dimension 6 Display control 7 Navigation in the Menu 7 Display Operation ...

Page 4: ...lly read this instruction manual in its entirety and keep it well for using reference This manual contained about the installation and the relative using information of this products Plese refere this manual s relative instruction when using this equipment ...

Page 5: ...consider that damages caused by manual modifications to the device are not subject to warranty Every person involvd with installation and maintenance of this device to Be qualilfied Follow the instructions of this manual 1 Never let the power cord come into contact with other cables Handle the power cord and all connections with particular caution Make sure that the available voltage is not higher...

Page 6: ...ade to a power supply system fitted with efficient earthing Class I app liance according to standard EN 60598 1 It is moreover recommended to protect the supply lines of the projectors from indirect contact and orshorting to earth by using appropriately sized residual current devices The projector needs to be positioned so that the objects hit by the beam of light are at least Safety of electrical...

Page 7: ...m which are put to use here 4 2 Installing the Clamps Please consider the respective national norm s during the Installation The installation must only be car ried out by an authorized dealer The installation of the projector has to be built and constructed in a way that it can hold 10 times the wei ght for 1 hour without any harming deformation The installation must always be secured with a secon...

Page 8: ...ght 4 The projector can be placed directly on the stage floor or rigged in any orientation on atruss without alte ring its operation characteristics For overhead use always install a safety rope that can hold at least 10 times the weight of the fixture You must only use safety ropes with screw on carabines Pull the safety rope through the two apertures on the bottom of the base and over the trussi...

Page 9: ...electrically noisy environment it is recommended to use a DMX terminator This help in preventing corruption of the signal by electrical noise The DMX terminato r is simply an XLR plug witha 120 resistor connected between pins 2 and pins3 which is then plugged into a the output XLR socket of the last ifxture in the chain Ω 1 2 3 120Ω PIN2 PIN3 DMX512 Max loop 3 fixture at 110V Max loop 6 fixture at...

Page 10: ...e 6 Dimension 1 2 4 7 8 9 Power In Power Out ENTER button DOWN button UP button MODE button LED display 10 Respirator 3 pin XLR male 3 3 pin XLR female 5 6 1 2 3 4 5 6 7 8 9 10 1008mm 85mm 166mm 1 25 lens 2 6 15 45 60 lens Optional ...

Page 11: ...of the lamp The specific contents shows as the table menu below Set or browse lighting function press UP or DOWN button Press ENTER to save your changes or enter the submenu Press the UP or DOWN can change the nume rical increase or decrease in value Press the MODE button to return to menu When the power on if the display is flashing it indicates that the DMX signal connection is unnormal Once pow...

Page 12: ...5 CTO 0 255 Pattern 0 255 Pattern Speed 0 255 Pattern Fade 0 255 Linear Theatrical Square Law Inverse Square Fast Smooth 600 Hz 1200 Hz 2400 Hz 4800 Hz 9600 Hz Off 1 minute 5 minute 60 minute No signal flash On Off Auto Off On Celsius Fahrenheit Off ON Set password Yes NO Auto DMX Static Temperature Unit Lock Shut off time Flip Display Dimmer Curve Dimmer Speed DMX Mode No DMX Personality PWM Disp...

Page 13: ... Time 000 999 Fade Time 000 999 Program 2 3 See above Program Play Program 1 2 3 Program Reset Program 1 2 3 All Reset Fixture Reset Reset Cancel Red 0 255 0 Green 0 255 0 Blue 0 255 0 White 0 255 0 Red 0 255 255 Green 0 255 255 Blue 0 255 255 White 0 255 255 LED Protect 0 255 100 Factory Default NO Yes Resettable xxx H xxM Total xxx H xxM Clear Resettable Clear Cancel Actual xxx C F Max xxx C F R...

Page 14: ...122 Fern Green 116 120 LEE 738 JAS Green 121 125 LEE 088 Lime Green 126 130 LEE 100 Spring Yellow 131 135 LEE 104 Deep Amber 136 140 LEE 179 Chrome Orange 141 145 LEE 105 Orange 146 150 LEE 021 Gold Amber 151 155 LEE 778 Mellennium Gold 156 160 LEE 135 Deep Golden Amber 161 165 LEE 164 Flame Red 166 170 Coulourwheel rotation forward fast slow 171 185 Coulourwheel rotation stop 186 190 Coulourwheel...

Page 15: ... 1 White Pattern 1 White 0 100 0 255 21 Pattern 1 Shutter Pattern Shutter 0 255 22 Pattern 1 Dimmer Pattern 1 Dimmer 0 100 0 255 No Effect 0 5 Static Pattern 6 61 No Effect 62 79 Animated Pattern 80 163 Random Pixel 164 179 No Effect 180 255 24 Pattern 2 Speed Pattern 2 Speed 0 100 0 255 25 Pattern 2 Fade Pattern 2 Fade 0 100 0 255 26 Pattern 2 Red Pattern 2 Red 0 100 0 255 27 Pattern 2 Green Patt...

Page 16: ... 0 100 0 255 19 Green 2 Green 2 0 100 0 255 20 Blue 2 Blue 2 0 100 0 255 21 White 2 White 2 0 100 0 255 22 Red 3 Red 3 0 100 0 255 23 Green 3 Green 3 0 100 0 255 24 Blue 3 Blue 3 0 100 0 255 25 White 3 White 3 0 100 0 255 26 Red 4 Red 4 0 100 0 255 27 Green 4 Green 4 0 100 0 255 28 Blue 4 Blue 4 0 100 0 255 29 White 4 White 4 0 100 0 255 30 Red 5 Red 5 0 100 0 255 31 Green 5 Green 5 0 100 0 255 32...

Page 17: ...White 10 0 100 0 255 54 Red 11 Red 11 0 100 0 255 55 Green 11 Green 11 0 100 0 255 56 Blue 11 Blue 11 0 100 0 255 57 White 11 White 11 0 100 0 255 58 Red 12 Red 12 0 100 0 255 59 Green 12 Green 12 0 100 0 255 60 Blue 12 Blue 12 0 100 0 255 61 White 12 White 12 0 100 0 255 Standard Advanced Pixel Compressed RGBW Fade Type Function Dmx Value ...

Page 18: ... lens will require weekly cleaning as smoke fluid tends to building up residues reduc ing the light output very quickly The cooling fans should be cleaned monthly The gobos may be cleaned with a soft brush The interior of the fixture should be cleaned at least annua lly usinga vacuum cleaner or an air jet There are no serviceable parts inside the device except for the lamp and the fuse Replacing t...

Page 19: ...hannel Characteristics 2 Demme r limear dimme r 3 Shutter electronic shutter random strobe 4 LED individual control preseting automatical temperature control system 1 Channel 13 32 61 5 DMX 512 10 4 Menu Function 2 Display the time using of lighting feature and lamp as well as the times of turning on for lamp 3 4 Software upgrade function 1 O After the DMX signal is disconnected the display will b...

Page 20: ...specification you have on hand and our company reserves the final right of interpretation 11 Electronic drawing G AC220V N L G PSU 1 2 3 1 2 3 N L G N L G IN AC220V OUT AC220V DC36V N L 1 2 3 4 5 6 60 FAN1 60 FAN2 Displayer Board LED Control Board LED Board LED Board LED Board LED Board LED Board LED Board ...

Page 21: ......

Page 22: ...angsha Street Shachong Village shiji Tow Panyu District Guangzhou China http www jollylight ing com Guangzhou hongcai stage equipment Co Ltd Tel 862084558833 Fax 862084559699 Email info jollylighting com P C 511450 ...