Page
65
of
133
Version 3.0 REV r000
Date 25-08-2010
6.10
Operating Sonic Control on a second computer
There may be circumstances where it is preferred to run Sonic Control on a different computer than
the computer where the data collection software is running. With the IP Discover firmware, the
user can change IP addresses as well as UDP ports. By doing Discover (in Settings | Network
Settings), the system looks for all attached R2Sonic equipment, which will be indentified by model
and serial number. Once the serial number is discovered, it is used to assign an IP and UDP port to
the sonar head and the SIM, after this is done, the IP and UDP ports can be changed.
6.10.1
Two computer setup
1)
Set the data collection computer’s networking to IP address 10.0.1.102 as usual
2)
Setup Sonic Control, on the data collection computer, as normal: do Discover and apply the
settings to establish communication with the system
3)
Set the second computer’s networking to IP address 10.0.1.105 (using this as an example)
4)
Load Sonic Control on the second computer, but do not connect the second computer to the
SIM until directed to below
5)
Open Sonic Control on the second computer
6)
Go to Settings | Network settings and change only the GUI IP address to 10.0.1.105 (see
illustration below)
7)
Connect a LAN cable from the second computer to one of the free RJ45 ports on the SIM
(there will now be 2 Ethernet cables connected to the SIM)
8)
On the data collection computer’s Sonic Control, go to Settings | Network Settings and
change only the GUI IP to the IP of the second computer: 10.0.1.105 (see illustration below)
9)
Do not change any other IP or Port, only the IP for the GUI is to be changed
10)
Select Apply: the GUI, on the data collection computer, will no longer update nor will it be
able to control the multibeam
11)
On the second computer, open Sonic Control
12)
Under Network settings, use Discover to obtain the serial numbers of the SIM and sonar
head and Apply; this computer now controls the Sonic system.
13)
This example used IP address 10.0.1.105, but any IP can be entered as long as it adheres to
the restrictions set by the subnet mask
Summary of Contents for 2022
Page 1: ...SONIC 2024 2022 BROADBAND MULTIBEAM ECHOSOUNDERS Operation Manual V3 0 Part No 96000001 ...
Page 2: ...Page 2 of 133 Version 3 0 Rev r000 Date 25 08 2010 Part No 96000001 ...
Page 92: ...Figure 78 Smooth log information copied from real time survey log ...
Page 96: ...Page 96 of 133 Version 3 0 Rev r000 Date 25 08 2010 This page intentionally left blank ...
Page 112: ...Page 112 of 133 Version 3 0 Rev r000 Date 25 08 2010 This page intentionally left blank ...
Page 116: ...Page 116 of 133 Version 3 0 Rev r000 Date 25 08 2010 This page intentionally left blank ...
Page 125: ...Page 125 of 133 Version 3 0 REV r000 Date 25 08 2010 Figure 94 Sonic 2024 Receive Module ...