Page
40
of
133
Version 3.0 Rev r000
Date 25-08-2010
Part No. 96000001
6.2
Network Setup
All communication, between the Sonic 2024/2022 and the SIM and data collection computer is via
Ethernet. The first step in setting up the sonar system is to establish the correct Ethernet
parameters, which include the IP (Internet Protocol), Subnet Mask and UDP (User Datagram
Protocol)base port under Settings | Network settings.
6.2.1
Initial Computer setup for Communication
Prior to starting Sonic Control 2000 for the first time, the computer’s network parameters must be
set correctly to establish the first communication.
Open the computer’s network connections. Identify the NIC (Network Interface Card) that is being
used for the Sonic system and select Properties (usually by using the right mouse button context
menu, highlight the Internet Protocol (TCP/IP) and select properties. Select ‘
Use the following IP
address’
and enter:
IP address:
10.0.1.102
Subnet
mask:
255.0.0.0
Figure 32: Windows XP Internet Properties
Select Internet Protocol and then select Properties to enter the correct IP and Subnet mask.
Summary of Contents for 2022
Page 1: ...SONIC 2024 2022 BROADBAND MULTIBEAM ECHOSOUNDERS Operation Manual V3 0 Part No 96000001 ...
Page 2: ...Page 2 of 133 Version 3 0 Rev r000 Date 25 08 2010 Part No 96000001 ...
Page 92: ...Figure 78 Smooth log information copied from real time survey log ...
Page 96: ...Page 96 of 133 Version 3 0 Rev r000 Date 25 08 2010 This page intentionally left blank ...
Page 112: ...Page 112 of 133 Version 3 0 Rev r000 Date 25 08 2010 This page intentionally left blank ...
Page 116: ...Page 116 of 133 Version 3 0 Rev r000 Date 25 08 2010 This page intentionally left blank ...
Page 125: ...Page 125 of 133 Version 3 0 REV r000 Date 25 08 2010 Figure 94 Sonic 2024 Receive Module ...