3.3.1
How to control a D.C.voltage superior to 5V
Connect to DB25 marked as BALANCED ANALOG INPUT on the PIN described in
the table
Pin number
Meant
Adj. Trimmer
2 (+), 14 (
−
)
Analogic balanced input n°1
RV1
3 (+), 16 (
−
)
Analogic balanced input n°2
RV2
5 (+), 17 (
−
)
Analogic balanced input n°3
RV3
6 (+), 19 (
−
)
Analogic balanced input n°4
RV4
8 (+), 20 (
−
)
Analogic balanced input n°5
RV5
9 (+), 22 (
−
)
Analogic balanced input n°6
RV6
11 (+), 23 (
−
)
Analogic balanced input n°7
RV7
12 (+), 25 (
−
)
Analogic balanced input n°8
RV8
1, 4, 7, 10, 13, 15,
18, 21, 24
Massa
Obtain the maximum of the voltage and regulate the correspondent trimmer in order
to obtain the visualization, on the remote control software, the voltage of 5V. See the
software manual to set up correctly the database necessary to have an immediate
visualization of the parameter in the right unit of measure.
3.3.2
How to control a voltage inferior to 5V
Connect to DB25 marked as DIGITAL/ANALOG INPUT on the PIN described in the
table:
Pin number
Meant
Jumper su JP4
2
Digital/analogic unbalanced input n°1
pos. 1
15
Digital/analogic unbalanced input n°2
pos. 2
3
Digital/analogic unbalanced input n°3
pos. 3
16
Digital/analogic unbalanced input n°4
pos. 4
4
Digital/analogic unbalanced input n°5
pos. 5
17
Digital/analogic unbalanced input n°6
pos. 6
5
Digital/analogic unbalanced input n°7
pos. 7
18
Digital/analogic unbalanced input n°8
pos. 8
21
Digital/analogic unbalanced input n°9
pos. 9
9
Digital/analogic unbalanced input n°10
pos. 10
22
Digital/analogic unbalanced input n°11
pos. 11
10
Digital/analogic unbalanced input n°12
pos. 12
23
Digital/analogic unbalanced input n°13
pos. 13
11
Digital/analogic unbalanced input n°14
pos. 14
24
Digital/analogic unbalanced input n°15
pos. 15
12
Digital/analogic unbalanced input n°16
pos. 16
1, 6, 7, 8, 13, 14,
19, 20, 25
GND
Obtain the visualization, on the remote control software, of the parameter. See the
software manual to set up correctly the database necessary to have an immediate
visualization of the parameter in the right unit of measure.
Summary of Contents for TLC2000
Page 1: ...Manufactured by Italy TLC2000 User Manual LCD Version ...
Page 6: ...TLC2000 2 50 User Manual Rev 1 0 05 05 03 This page was intentionally left blank ...
Page 20: ...TLC2000 16 50 User Manual Rev 1 0 05 05 03 This page was intentionally left blank ...
Page 32: ...TLC2000 28 50 User Manual Rev 1 0 05 05 03 This page was intentionally left blank ...
Page 36: ...TLC2000 32 50 User Manual Rev 1 0 05 05 03 This page was intentionally left blank ...
Page 42: ...TLC2000 38 50 User Manual Rev 1 0 05 05 03 This page was intentionally left blank ...
Page 88: ...SCM TLC 32 50 User Manual Rev 1 0 17 01 03 This page was intentionally left blank ...
Page 98: ...SCM TLC 42 50 User Manual Rev 1 0 17 01 03 This page was intentionally left blank ...
Page 104: ...SCM TLC 48 50 User Manual Rev 1 0 17 01 03 This page was intentionally left blank ...
Page 106: ...SCM TLC 50 50 User Manual Rev 1 0 17 01 03 This page was intentionally left blank ...
Page 109: ...TLC2000 CSPTCPU55202 1 4 Appendice Tecnica Rev 1 1 08 10 02 ...
Page 113: ...TLC2000 CSSWPSUP0003 1 4 Appendice Tecnica Rev 1 0 10 09 01 ...
Page 117: ...TLC2000 CSTLSCCPU002 1 4 Appendice Tecnica Rev 1 1 27 05 03 ...
Page 121: ...TLC2000 CSTLMINP1 01 1 4 Appendice Tecnica Rev 1 0 10 09 01 ...
Page 125: ...TLC2000 CSTLMANABI01 1 4 Appendice Tecnica Rev 1 0 10 09 01 ...