Set the Demodulator Target Server (To) IP Address
Press the top switch to cycle to the Target IP Address Setup. The message
“Destination IP Address” will be briefly displayed followed by the display
below.
Figure 21 - Demodulator Target Server IP Address Screenshot
Press the bottom switch to cycle through the address digits displayed above the
caret symbol and press the top switch to move to the next digit. Setup is aware
of valid addresses and will allow you to set this to any valid IPv4 address. If
you set this to a multicast address, your data reception application may require
additional configuration to set up a multicast path to your server and any
Ethernet switch present in the path may also require configuration.
If you don’t want to change this address, just continue to press the top switch
past all of the digits to get to the next setting.
If the TO IP Address has been changed the message “Setting TO IP Addr” will
be displayed and a short delay will occur while this address is changed in the
Linux Data Processing Sub-system and the data processing tasks are restarted.