GRB-200 Demodulator (GOES-R) OI&M
GRB-200 Demodulator (GOES-R) OI&M
© Copyright 2015, Quorum Communications, Inc.
Revision A.01
24
3.2 CONFIGURING THE DEMODULATOR
Default Configuration
3.2.1
When powered up for the first time or when set to default configuration by
using the front panel switches, the demodulator is configured as follows:
•
Both the LHCP and RHCP demodulators are set to 8PSK mode and No
Spectrum Inversion
•
The IP Address of the demodulator is set to 192.168.123.100 (MY IP)
•
The IP Address of the target server is set to 192.168.123.105 (TO IP)
•
The Temperature Alarm Limit is set to 61 C.
Additionally, certain parameters generally inaccessible by the user are reset.
•
The UDP port for the LHCP data is set to 50010
•
The UDP port for the RHCP data is set to 50020
•
The UDP port for the Status data is set to 50030
•
Both the LHCP and RHCP channels are set to transmit CADUs
•
Manufacturing and diagnostic test modes are disabled.