Instruction book
2920 7101 22
95
UL/cUL approval
Compressor specification
I(1)
Max Fuse
(1)
I(2)
Max Fuse
(2)
Type
gL/gG
gL/gG
V Hz A A A A
A1 75kW 230 60 276 300 -
-
A2 75kW 230 60 273 300 -
-
X 75kW 230 60 273 300 -
-
A1 75kW 460 60 138 150 -
-
A2 75kW 460 60 136 150 -
-
X 75kW 460 60 136 150 -
-
A2 75kW 575 60 109 125 -
-
X 75kW 575 60 109 125 -
-
UL/cUL approval
Compressor specification
I(1)
Max Fuse
(1)
I(2)
Max Fuse
(2)
Type
gL/gG
gL/gG
V Hz A A A A
A1 110kW 460 60 205 225 -
-
A1 110kW 575 60 162 175 -
-
I: current in the supply lines at maximum load and nominal voltage
(1): compressor without integrated dryer
(2): compressor with integrated dryer
Fuse calculations for IEC
are done according to 60364-4-43 low-voltage electrical installations, part 4-43:
protection against overcurrent. Fuse sizes are calculated in order to protect the cable against short circuit.
Fuse type aM is recommended for fixed speed units. Fuse type gL/gG is also allowed and mandatory for
variable speed units.
Fuse calculations for cUL and UL
: The indicated fuse size is the maximum fuse size in order to protect
the motor against short circuit. For cUL fuse HRC form II, for UL fuse class RK5.
Possible configurations
There are 3 possible cabling layouts: