Instruction book
116
2920 7101 22
10.2.4.4 During operation
The ECOi main screen will be similar to the one below.
ECO main screen
Reference
Description
(1)
Compressor 1 is stopped
(2)
Compressor 2 is running local
(3)
Compressor 3 : No communication between regulator and related slave
(4)
Compressor 4 is starting up
(5)
Compressor 5 : Master VSD is loaded
(6)
Compressor 6 : No valid compressor type
(7)
The maximum pressure is set on 8.0 bar
The minimum pressure is set on 7.0 bar
The actual pressure is 7.4 bar
10.2.4.5 Isolating a compressor
It is possible to isolate a compressor from regulation by the master regulator.
1. On the regulator of the compressor to be isolated use the scroll buttons to select the icon LAN Control
on the main screen.
2. Press the enter button.
3. Scroll to Local control in this list.
4. Press the enter button.
5. The icon Local Control appears on the main screen.
10.2.4.6 Integrating a compressor
To integrate an isolated compressor again:
1. On the regulator of the compressor to be itegrated use the scroll buttons to select the icon Local
Control on the main screen.
2. Press the enter button.
3. Scroll to LAN Control in this list.
4. Press the enter button.
5. The icon LAN Control appears on the main screen