66
2920 7101 22
Transport fixtures
3. Check that the electrical connections correspond to the local codes and that all wires are clamped tight
to their terminals.
The installation must be earthed and protected against short circuits by fuses of the inert type in all
phases. An isolating switch must be installed near the compressor.
4. Check transformer (T1) for correct connection.
Check the settings of drive motor overload relay (F21).
Check that the motor overload relay is set for manual resetting.
Electric cubicle, typical example
5. Fit the air outlet valve (AV); see section
Introduction
for the position of the valve.
Close the valve.
Connect the air net to the valve.
6. Connect the automatic drain outlet (Da) to a drain collector.