Instruction book
74
2920 7101 22
■
OPERATIONS THAT MAY BE CARRIED OUT BY THE USER
■■
OPERATIONS THAT REQUIRE SKILLED PERSONNEL
Interval operations
Every Day (after use)
Check automatic condensation drain (dryer)
Every 50 working hours
Drain condensate from the oil tank
Check the oil level
Clean the filter of the automatic condensate drain (dryer)
Every 500 hours
Replace oil filter (at first 500 hrs)
Tighten the screws fixing the electric cables (at first 500 hrs)
Clean the air inlet filter
Clean the condenser heat exchanger (unit with dryer)
Clean the inlet filtration panels
Every 2000 hours
Replace the inlet air filter
Replace the oil filter
Retighten all power cable connections
Safety temperature test
Maintenance kit of the automatic condensate drain (dryer)
Oil Fluid sample
Every 4000 hours
Clean the finned surface of the air-oil cooler
Replace the oil separator filter
Every 8000 hours
Intake service kit
Check status of oil return valve and oil pipes
MPV Service kit
Replace the oil *
Every 12000 hours
Unloader valve kit
Oil-stop- and check-valve kit
Minimum pressure valve kit
Thermostatic valve kit
*
The
compressor
must
be
maintained
with
QuinSyn
‐
Plus
(8,000
hour
maximum),
QuinSyn
‐
XP
(12,000
hour
maximum)
or
QuinSyn
‐
F
food
grade
(6,000
hour
maximum).
Maximum
fluid
change
intervals
are
noted
per
fluid.
Actual
fluid
change
interval
is
to
be
determined
by
fluid
sampling
report,
not
to
exceed
maximum
fluid
change
interval.
Fluid
samples
must
be
taken
every
2,000
hours
or
as
directed
by
the
analysis
report.
For
light
usage
units,
a
fluid
sample
must
be
taken
a
minimum,
of
every
six
(6)
months,
beginning
at
start
‐
up.
Summary of Contents for QGS 40
Page 2: ......
Page 131: ......
Page 132: ...Performance You Demand Reliability You Trust www quincycompressor com COMPRESSOR...