5. 

Then, tie the black wire from the power source to the black wire from the timer. 

6. 

Lastly, tie the copper ground wire from the power source to the copper ground wire from the timer.

4. SYSTEM OPERATING INSTRUCTIONS

4.1  QuietCool Smart Attic Fan

QuietCool Attic Fans work almost everywhere, almost anytime. During the summer, an attic can be 40-50 
degrees hotter than the outside temperature, which in turn heats up the house much faster. With an attic fan, 
you can cool the attic to the same temperature as it is outside, greatly reducing the house from heating as 
quickly.

With the QuietCool Smart Attic Fan, gone are the days of having to adjust the thermostat for your attic fan. 
Featuring a built-in thermostat and humidistat, the self-adjusting, 10-speed ECM motor is always reading the 
temperature and humidity in the attic. 

When the fan detects temperature over 80 degrees, or humidity over 60%, the Smart Attic Fan comes on at the 
lowest speed. As the attic starts to heat up, the Smart Attic Fan automatically adjusts it’s speed. 

Temp.

80°

85°

90°

95°

100°

105°

110°

115°

120°

125°+

Humidity

60%+

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

Speed

1

2

3

4

5

6

7

8

9

10

CFM

963

1343

1513

1641

1841

2014

2119

2356

2500

2830

Watts

15

18

25

34

49

60

79

99

117

145

*All specs are approximate. For the most up-to-date specs, please visit QuietCoolSystems.com

Figure 3.3A

Ground the fan to the junction box 

using the green ground screw

Specialty Series Fan

Junction

Box

Power

Source

14-2 Wire

14-2 Wire

8 HOUR

4 HOUR

2 HOUR

1 HOUR

HOLD

Bare Copper Wires Tied 

Together

Match Wire

Colors Together

14-3 W

ire

ADVANCED ATTIC GABLE FANS

®

Ground the fan to the junction box 

using the green ground screw

Specialty Series Fan

Junction

Box

Power

Source

14-2 Wire

14-2 Wire

8 HOUR

4 HOUR

2 HOUR

1 HOUR

HOLD

Bare Copper Wires Tied 

Together

Match Wire

Colors Together

14-3 W

ire

ADVANCED ATTIC GABLE FANS

®

Summary of Contents for AFG SMT-3.0

Page 1: ...SEE HEAR FEEL THE QUIETCOOL DIFFERENCE ADVANCED WHOLE HOUSE FANS THE NATURAL CHOICE FOR ENERGY SAVINGS INSTALLATION GUIDE SPECIALTY SERIES FANS...

Page 2: ...em The user should not attempt to service the product 7 Building Codes Always follow Local Building Codes when installing appliances CONTENTS 1 SYSTEM OVERVIEW 1 1 1 Introduction 1 1 2 Features 1 1 3...

Page 3: ...ergy efficient too We also have the AFG PRO 3 0 the most powerful residential attic fan on the market QuietCool Garage Fans The QuietCool Garage Fans offer great ventilation options for your garage ma...

Page 4: ...1 SQUARE FOOT OF NET FREE VENT AREA PER 750 CFM RECOMMENDED 2 TO 4 SQUARE FEET OF INLET VENTS PER FAN Vent Type Model Type Average Size Venting Sq Ft Gable vent 12 x 19 5 1 20 Dormer Vent 14 x 8 0 70...

Page 5: ...an be mounted flush to a rectangular type louver by fastening through the mounting brackets to the frame of the louver as shown in Figure 2 1A As stated in the note above any area of the louver that i...

Page 6: ...to install your QuietCool Garage Attic Fan Now it s time to find the exact location using a stud finder Locate the ceiling studs and mark the location for the fan to be installed see Figure 2 2A One s...

Page 7: ...l saw cut out the opening Remove the drywall cutout and clear away insulation if applicable see Figure 2 2C 4 From the interior drill a hole through the exterior at the four corners of the cut out see...

Page 8: ...utting the roof If you are installing the RM ES 1100 mark a 14 1 4 x 14 1 4 square If you are installing the RM ES 2200 mark a 16 1 4 x 16 1 4 square see Figure 2 4A 3 Move to the roof and using a cir...

Page 9: ...level of the fan NEVER install the ceiling grille directly underneath the fan Always offset at least two feet Figure 2 4A Figure 2 4B Figure 2 4C Figure 2 4D Roof Mount Application Diagrams Flat Roof...

Page 10: ...t tie the white common wire together Then tie the black wires together 4 Ground the green wire from the fan and the ground wire from the Romex to the junction box NOTE When the Smart Attic Fan is conn...

Page 11: ...ex junction box and a thermostat 2 Open up the thermostat that is connected to the fan Remove the power cord Remove the bracket mounting the thermostat to the flex tubing and remove the thermostat 3 M...

Page 12: ...two red wires together the two white wires together the two black wires together and the two ground wires together 3 Open up the junction box that is connected to the fan Bring your 2 wire and 3 wire...

Page 13: ...ic When the fan detects temperature over 80 degrees or humidity over 60 the Smart Attic Fan comes on at the lowest speed As the attic starts to heat up the Smart Attic Fan automatically adjusts it s s...

Page 14: ...uced the heat transfer between the attic and garage on really hot days Our GX ES 1100 works well to cool and ventilate your garage Run both of these fans when it is cooler outside than it is in your g...

Page 15: ...the original date of purchase C This warranty does not cover any of the following 1 Incidental or consequential damage resulting from the operation of our equipment or any malfunction thereof 2 Cost...

Page 16: ...14 1 888 QUIETCOOL ADVANCED WHOLE HOUSE FANS QuietCool is Proudly Designed and Built in California 43352 Business Park Drive Temecula CA 92590 PH 951 325 6340 QUIETCOOLSYSTEMS COM...

Reviews: