background image

4

QUIETCOOLSYSTEMS.COM

Odd Mount: 

The AFG can also be mounted off center for an 

odd shaped louver 

(as shown in Figure 2.1C)

.  

 
As stated in the note above, any area of the louver that is not 
covered by the AFG must be sealed off in order to prevent air 
leakage, which may hinder performance. 
 
While this is not the most ideal way to mount the gable fan, it 
is possible. However, since the fan is not completely covering 
the vent, maximum airflow will not be achieved. 
 
 
   

NOTE:

 The AFG can be mounted on many other types of louvers, including triangle  

 

 

   vents, round vents, half-round vents, etc. If the vent is smaller than the area of the    

 

   fan, we recommend constructing a chamber that surrounds the vent, and then mount 

 

   the AFG to the chamber to ensure maximum airflow and performance.

 

2.2  Installing GA model fans

 

     

 

  VERY IMPORTANT: 

MINIMUM OF 26” CLEARANCE REQUIRED ABOVE CEILING FOR  

                

 

  INSTALLATION OF GA MODEL FANS. ALWAYS FOLLOW LOCAL BUILDING CODES.

 

1. 

Determine in which area you would like to install your QuietCool Garage Attic Fan. Now it’s time to find 
the exact location using a stud finder. Locate the ceiling studs and mark the location for the fan to 
be installed. 

(see Figure 2.2A)

 One side of the cut out should be directly next to a wood member for 

proper fan mounting and support.

2. 

When you find the location, mark a 14 1/4” square using a framing square or template. Make sure you 
have 2” of clearance all the way around it. The grille that will be installed later is a 16” square. 

(see 

Figure 2.2B)

3. 

Starting at one corner of the square using a drywall saw, cut out the opening. Remove the drywall 
cutout and clear away insulation (if applicable).

 (see Figure 2.2C)

4. 

Take the GA fan model into the attic and place it over the ceiling cut out. Attach the fan using screws 
into the ceiling joists. 

(see Figure 2.2D)

. Install the ceiling grille.

 (see Figure 2.3H)

 

 

   VERY IMPORTANT: 

CHECK TO MAKE SURE FAN BLADE SPINS FREELY AND THE FIRE DAMPER    

          CLOSES EASILY. MAKE SURE TO SECURE THE LATCH IN THE OPEN POSITION
 
 

   

AVOID BACKDRAFTS: 

MAKE SURE THE GARAGE FAN WILL NOT BACKDRAFT COMBUSTION   

 

 

   APPLIANCES IN THE GARAGE. QUIETCOOL GARAGE FANS MOVE LARGE QUANTITIES OF AIR.

Figure 2.1C

Summary of Contents for AFG SMT-3.0

Page 1: ...SEE HEAR FEEL THE QUIETCOOL DIFFERENCE ADVANCED WHOLE HOUSE FANS THE NATURAL CHOICE FOR ENERGY SAVINGS INSTALLATION GUIDE SPECIALTY SERIES FANS...

Page 2: ...em The user should not attempt to service the product 7 Building Codes Always follow Local Building Codes when installing appliances CONTENTS 1 SYSTEM OVERVIEW 1 1 1 Introduction 1 1 2 Features 1 1 3...

Page 3: ...ergy efficient too We also have the AFG PRO 3 0 the most powerful residential attic fan on the market QuietCool Garage Fans The QuietCool Garage Fans offer great ventilation options for your garage ma...

Page 4: ...1 SQUARE FOOT OF NET FREE VENT AREA PER 750 CFM RECOMMENDED 2 TO 4 SQUARE FEET OF INLET VENTS PER FAN Vent Type Model Type Average Size Venting Sq Ft Gable vent 12 x 19 5 1 20 Dormer Vent 14 x 8 0 70...

Page 5: ...an be mounted flush to a rectangular type louver by fastening through the mounting brackets to the frame of the louver as shown in Figure 2 1A As stated in the note above any area of the louver that i...

Page 6: ...to install your QuietCool Garage Attic Fan Now it s time to find the exact location using a stud finder Locate the ceiling studs and mark the location for the fan to be installed see Figure 2 2A One s...

Page 7: ...l saw cut out the opening Remove the drywall cutout and clear away insulation if applicable see Figure 2 2C 4 From the interior drill a hole through the exterior at the four corners of the cut out see...

Page 8: ...utting the roof If you are installing the RM ES 1100 mark a 14 1 4 x 14 1 4 square If you are installing the RM ES 2200 mark a 16 1 4 x 16 1 4 square see Figure 2 4A 3 Move to the roof and using a cir...

Page 9: ...level of the fan NEVER install the ceiling grille directly underneath the fan Always offset at least two feet Figure 2 4A Figure 2 4B Figure 2 4C Figure 2 4D Roof Mount Application Diagrams Flat Roof...

Page 10: ...t tie the white common wire together Then tie the black wires together 4 Ground the green wire from the fan and the ground wire from the Romex to the junction box NOTE When the Smart Attic Fan is conn...

Page 11: ...ex junction box and a thermostat 2 Open up the thermostat that is connected to the fan Remove the power cord Remove the bracket mounting the thermostat to the flex tubing and remove the thermostat 3 M...

Page 12: ...two red wires together the two white wires together the two black wires together and the two ground wires together 3 Open up the junction box that is connected to the fan Bring your 2 wire and 3 wire...

Page 13: ...ic When the fan detects temperature over 80 degrees or humidity over 60 the Smart Attic Fan comes on at the lowest speed As the attic starts to heat up the Smart Attic Fan automatically adjusts it s s...

Page 14: ...uced the heat transfer between the attic and garage on really hot days Our GX ES 1100 works well to cool and ventilate your garage Run both of these fans when it is cooler outside than it is in your g...

Page 15: ...the original date of purchase C This warranty does not cover any of the following 1 Incidental or consequential damage resulting from the operation of our equipment or any malfunction thereof 2 Cost...

Page 16: ...14 1 888 QUIETCOOL ADVANCED WHOLE HOUSE FANS QuietCool is Proudly Designed and Built in California 43352 Business Park Drive Temecula CA 92590 PH 951 325 6340 QUIETCOOLSYSTEMS COM...

Reviews: