background image

13

1-888-QUIETCOOL

SPECIALTY SERIES FANS LIMITED WARRANTY

15 YEAR LIMITED WARRANTY 

PRODUCT INFORMATION 

QC Serial # 

QC Serial #

QC Serial # 

QC Serial # 

QUIETCOOL SPECIALTY SERIES FANS

QC Manufacturing Inc.  extends  this  warranty  to  the original purchaser of the following QuietCool 

Specialty  Series  Fans

  ---- 

AFG  SMT-3.0,  AFG  PRO-3.0

AFG  ES-1500

GA  ES-1500,

 

GX  ES-1100,  RM  ES-1100, 

RM ES-2200

 

---- installed and used in a residence under normal conditions within the United States: 

A.

Fifteen

 year coverage applies to the QuietCool motor fan assembly. At our option we will 

repair 

or

replace any part of the assembly should it fail to operate during the first 

fifteen

 years from 

the

date of original purchase.

B

.

One year coverage for all other components including grills, housings, controls and accessories

furnished by QC Manufacturing Inc. At our option we will repair or replace any part which fails as a

result of defective material or workmanship during the first year from the original date of purchase.

C

. This warranty does not cover any of the following:

1. Incidental or consequential damage resulting from the operation of our equipment or any

malfunction thereof.

2. Cost of service calls to diagnose the cause of problems or the labor charge to un-install any

components.

3. Product failure or damage due to faulty installation, abuse, misuse, unauthorized alteration to

factory specs, lack of maintenance, or transportation damage.

4. Shipping or postage for warranty claims.

D

.

To obtain service under this warranty, contact the dealer where you purchased the equipment.

If you are unable to find or reach your dealer, contact Customer Service at QC Manufacturing, Inc.,

at the 

number below

This warranty is the only warranty extended by QC Manufacturing, Inc. to purchasers or suppliers of our equipment. QC Manufacturing Inc. disclaims all other 

warranties, express or implied, that arise by operation of the law.

 

Rev.

3

.

29.17

 

E

.

Registration is no longer required for QuietCool fans. If service is required under this warranty,

you must retain your proof or purchase.

ADVANCED WHOLE HOUSE FANS

®

MAKERS OF THE QUIETCOOL ADVANCED WHOLE HOUSE FAN

Summary of Contents for AFG SMT-3.0

Page 1: ...SEE HEAR FEEL THE QUIETCOOL DIFFERENCE ADVANCED WHOLE HOUSE FANS THE NATURAL CHOICE FOR ENERGY SAVINGS INSTALLATION GUIDE SPECIALTY SERIES FANS...

Page 2: ...em The user should not attempt to service the product 7 Building Codes Always follow Local Building Codes when installing appliances CONTENTS 1 SYSTEM OVERVIEW 1 1 1 Introduction 1 1 2 Features 1 1 3...

Page 3: ...ergy efficient too We also have the AFG PRO 3 0 the most powerful residential attic fan on the market QuietCool Garage Fans The QuietCool Garage Fans offer great ventilation options for your garage ma...

Page 4: ...1 SQUARE FOOT OF NET FREE VENT AREA PER 750 CFM RECOMMENDED 2 TO 4 SQUARE FEET OF INLET VENTS PER FAN Vent Type Model Type Average Size Venting Sq Ft Gable vent 12 x 19 5 1 20 Dormer Vent 14 x 8 0 70...

Page 5: ...an be mounted flush to a rectangular type louver by fastening through the mounting brackets to the frame of the louver as shown in Figure 2 1A As stated in the note above any area of the louver that i...

Page 6: ...to install your QuietCool Garage Attic Fan Now it s time to find the exact location using a stud finder Locate the ceiling studs and mark the location for the fan to be installed see Figure 2 2A One s...

Page 7: ...l saw cut out the opening Remove the drywall cutout and clear away insulation if applicable see Figure 2 2C 4 From the interior drill a hole through the exterior at the four corners of the cut out see...

Page 8: ...utting the roof If you are installing the RM ES 1100 mark a 14 1 4 x 14 1 4 square If you are installing the RM ES 2200 mark a 16 1 4 x 16 1 4 square see Figure 2 4A 3 Move to the roof and using a cir...

Page 9: ...level of the fan NEVER install the ceiling grille directly underneath the fan Always offset at least two feet Figure 2 4A Figure 2 4B Figure 2 4C Figure 2 4D Roof Mount Application Diagrams Flat Roof...

Page 10: ...t tie the white common wire together Then tie the black wires together 4 Ground the green wire from the fan and the ground wire from the Romex to the junction box NOTE When the Smart Attic Fan is conn...

Page 11: ...ex junction box and a thermostat 2 Open up the thermostat that is connected to the fan Remove the power cord Remove the bracket mounting the thermostat to the flex tubing and remove the thermostat 3 M...

Page 12: ...two red wires together the two white wires together the two black wires together and the two ground wires together 3 Open up the junction box that is connected to the fan Bring your 2 wire and 3 wire...

Page 13: ...ic When the fan detects temperature over 80 degrees or humidity over 60 the Smart Attic Fan comes on at the lowest speed As the attic starts to heat up the Smart Attic Fan automatically adjusts it s s...

Page 14: ...uced the heat transfer between the attic and garage on really hot days Our GX ES 1100 works well to cool and ventilate your garage Run both of these fans when it is cooler outside than it is in your g...

Page 15: ...the original date of purchase C This warranty does not cover any of the following 1 Incidental or consequential damage resulting from the operation of our equipment or any malfunction thereof 2 Cost...

Page 16: ...14 1 888 QUIETCOOL ADVANCED WHOLE HOUSE FANS QuietCool is Proudly Designed and Built in California 43352 Business Park Drive Temecula CA 92590 PH 951 325 6340 QUIETCOOLSYSTEMS COM...

Reviews: