background image

BV-WF-01-LV WALL FAN 

Installation Guide

WARNING

Please read these instructions carefully before installing, operating, or servicing the fan. Retain this guide for future reference.

1

SERVICE PARTS

1

2

4

5

6

12

3

3

3

8

9

7

11

10

13

14

15

1. Grille

2. Sheet Metal Nut

3. Sheet Metal Screws 

4. Motor Mounting Bracket

5. Motor

6. Blade

7. Wiring Box Cover

8. Green Ground Screw

9. Wiring Box

10. Housing 

11. Receptacle 

12. Spring

13. Adjustable Duct

14. Wall Cap

15. Aluminum Ring

TO REDUCE THE RISK OF FIRE, ELECTRIC 

SHOCK, OR INJURY TO PERSONS, OBSERVE 

THE FOLLOWING:

1.  Use this unit only in the manner intended 

by the manufacturer. If you have questions, 

contact the manufacturer at the address or 

telephone number listed in the warranty.

2.  Before servicing or cleaning unit, switch 

power off at service panel and lock the service 

disconnecting means to prevent power from 

being switched on accidentally. When the 

service disconnecting means cannot be 

locked, securely fasten a prominent warning 

device, such as a tag, to the service panel.

3.  Installation work and electrical wiring must be 

done by a qualified person(s) in accordance 

with all applicable codes and standards, 

including  fire-rated  construction  codes  and 

standards.

4. 

Sufficient air is needed for proper combustion 

and  exhausting  of  gases  through  the  flue 

(chimney)  of  fuel  burning  equipment  to 

prevent backdrafting. Follow the heating 

equipment manufacturer’s guideline and 

safety standards such as those published 

by the National Fire Protection Association 

(NFPA),  and  the  American  Society  for 

Heating, Refrigeration and Air Conditioning 

Engineers  (ASHRAE),  and  the  local  code 

authorities.

5.  When cutting or drilling into wall or ceiling, do 

not damage electrical wiring and other hidden 

utilities.

6.  Ducted fans must always be vented to the 

outdoors.

7.  This unit must be grounded.

8. 

To reduce risk of fire, use only metal ductwork.

9.  The electric service supply voltage must be 

120V 60HZ.

1.  For general ventilating use only. Do not use 

to exhaust hazardous or explosive materials 

and vapors.

2.  To avoid motor bearing damage and noisy 

and/or unbalanced impellers, keep drywall 

spray, construction dust, etc. off power unit.

3. 

Please read specification label on product for 

further information and requirements.

4.  Do not use in the bathroom.

5.  To reduce the risk of injury, install fan at least 

2.1m (7 feet) above the floor.

CAUTION

USE AND CARE

WARNING

: Switch off power at service panel and 

lock service panel before cleaning or servicing 

this fan.

TO CLEAN FAN ASSEMBLY:

Unplug motor from receptacle. Remove the motor 

assembly by loosening the mounting screws and 

rotating the motor assembly. 
Gently vacuum motor assembly and inside of 

housing.
METAL AND ELECTRICAL PARTS SHOULD 

NEVER BE IMMERSED IN WATER.
PERIODCALLY CHECK THE OUTER LOUVER 

FOR ACCUMULATED DUST, LINT, ETC., 

WHICH MAY INTERFERE WITH PROPER 

LOUVER CLOSURE.

WARNING

: DO NOT SPRAY WATER INTO 

LOUVER—DAMAGE TO THE FAN COULD 

OCCUR AND WATER COULD ENTER HOUSE.
There is no need to oil the motor on this fan.

WIRING DIAGRAM

AUTOMATIC TERMINAL SWITCH

FAN HOUSING

JUNCTION BOX

TO 120V/60HZ

BLACK WIRE

WHITE WIRE

GREEN WIRE

Summary of Contents for BV-WF-01-LV

Page 1: ...blished by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities 5 When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities 6 Ducted fans must always be vented to the outdoors 7 This unit must be grounded 8 To reduce risk of fire use only m...

Page 2: ...en wire to box using green ground screw NOTE Fan can be installed in outside walls up to 10 thick Walls less than 6 thick will not use the adjustable duct Choose a location with no obstructions Fan can be operated by a wall switch or speed control available separately WARNING When cutting or drilling into wall do not cut existing electrical wiring CAUTION Do not mount fan above cooking surface CAU...

Page 3: ...ly including inside and outside wall coverings Stretch the adjustable duct slide it over the housing and tape it in place non tapered end of flexible duct may need to be shortened to fit Position fan housing in wall Drill pilot holes through center of slots in mounting flange 4 6 5 TAPE HERE ...

Page 4: ... TAPE HERE 8 CAULK EDGES 9 Complete this step only if adjustable duct is used From outside slip adjustable duct into the aluminum ring attached to the wall cap and tape the joint Compress the excess duct back into the opening by positioning the wall cap against the outside wall Fasten wall cap to outside wall with screws and caulk around the edges ...

Page 5: ... quality product It was made with care and BV offers a limited one year warranty against any manufacturing defects as long as it has been used as directed BV will replace any product showing such manufacturing defects This warranty does not include labor costs for the installation or removal of the fan For warranty assistance call 866 721 3888 5 MOUNTING SCREW ...

Page 6: ...etiqueta al panel de servicio 3 El trabajo de instalación y el cableado eléctrico deben ser realizados por personas calificadas de acuerdo con todos los códigos y estándares aplicables incluidos los códigos y estándares de construcción con clasificación de resistencia al fuego 4 Se necesita suficiente aire para la combustión adecuada y el escape de gases a través de la chimenea del equipo de combu...

Page 7: ... tornillo de tierra verde NOTA El ventilador se puede instalar en paredes exteriores de hasta 10 de grosor Las paredes de menos de 6 de grosor no utilizarán el conducto ajustable Elija un lugar sin obstrucciones El ventilador puede ser operado por un interruptor de pared o control de velocidad disponible por separado ADVERTENCIA Al cortar o taladrar en la pared no corte el cableado eléctrico exist...

Page 8: ...es interiores y exteriores Estire el conducto ajustable deslícelo sobre el alojamiento y péguelo con cinta adhesiva en su lugar es posible que sea necesario acortar el extremo no cónico del conducto flexible Coloque el alojamiento del ventilador en la pared Taladre agujeros piloto a través del centro de las ranuras en la brida de montaje 4 6 5 CINTA ADHESIVA AQUÍ ...

Page 9: ...aso solo si se utiliza un conducto ajustable Desde el exterior deslice el conducto ajustable dentro del anillo de amluminio unido a la tapa de la pared y pegue con cinta adhesiva el conjunto Comprima el exceso del conducto de nuevo en la abertura colocando la tapa de la pared contra la pared exterior Sujete la tapa de la pared a la pared exterior con tornillos y calafatee alrededor de los bordes C...

Page 10: ...d Fue hecho con cuidado y BV ofrece una garantía limitada de un año contra cualquier defecto de fabricación siempre que se haya utilizado según las instrucciones BV reemplazará cualquier producto que muestre tales defectos de fabricación Esta garantía no incluye los costos de mano de obra para la instalación o extracción del ventilador Para asistencia con la garantía llame al 866 721 3888 10 10 TO...

Reviews: