2.0 Marine Diagnostics
42
Reference Manual
1- Mercury Marine
NOTE: Pressing 0 clears the minimum/maximum values.
To view sensors on screen number 2, press the
↑
or
↓
key until the
sensors for screen 2 are displayed. Press ENTER to view the
expanded screen for the sensor positioned opposite of the < caret.
FUEL LEVEL
180
<E
AVAILABLE PWR% 100
TRIM
38
PITOT
26.0
R
→
←
→
←
AVAILABLE PWR%
NOW:
min:
max:
100
100
100
R
<
Caret
E
Expanded mode available
→
Moves the caret down
←
Moves the caret up
R
When data can be recorded
NOW: Current value
min: Minimum value
max: Maximum value
→
←
a
b
FUEL LEVEL
NOW:
min:
max:
180
180
180
R
→
←
TRIM
NOW:
min:
max:
38
38
38
R
PITOT
NOW:
min:
max:
26.0
26.0
38.0
R
←
→
←
→
ENGINE RPM
650 <E
BATTERY VOLTS
14.3
PWR 1 VOLTS
5.0
MAP PSI
8.8
R
a-Screen 1
b-Screen 2
When the Data Monitor is reading data, you can press the RECORD
key at any time to record four parameters currently displayed. The
record function will also save the status of the LED indicators. See the
Record/Playback section of this manual.
Line Lock
Available
Record
Available
Press F2, 1
Available
Summary of Contents for SmartCraft Systems
Page 9: ...Preface 7 Reference Manual NOTES...
Page 28: ...1 0 Introduction 26 Reference Manual NOTES...
Page 29: ...2 0 Marine Diagnostics 27 Reference Manual OVERVIEW 1 Mercury Marine...
Page 98: ...2 0 Marine Diagnostics 96 Reference Manual NOTES...
Page 107: ...3 0 Glossary of Terms 105 Reference Manual NOTES...