2.0 Marine Diagnostics
50
Reference Manual
1- Mercury Marine
PLEASE WAIT READING
ECM DATA.....
If there is data stored in the Freeze Frame buffer, a menu list is
displayed which actually identifies the fault that triggered the freeze
frame event.
Make sure the FREEZE FRAME menu screen is displayed on the
DDT.
FREEZE FRAME BUFFERS
0-BREAK-IN
1-DINJ6 OPEN
2-PORT OVERHEAT
FREEZE FRAME BUFFERS
NO STORED FAULTS
PRESS MODE TO EXIT
or
Press the 1 key. Direct Injector 6 or its connection triggered this event.
You will now be able to view engine system data at the exact time the
fault was recorded.
↓
The barometric pressure when the fault occurred.
The battery voltage when the fault occurred.
The engine block pressure when the fault occurred.
←
←
DINJ 6 OPEN
BARO PSI
14.1
BATT VOLTS
14.6
BLOCK PSI
5.3
←
BOAT SPEED
0.0
AIR TMP
F
78.8
COOL TMP
F
127
DEMAND %
0.0
↑
↓
←
←
←
←
Boat speed when the fault occurred.
The engine temperature when the fault occurred.
The primary (CTS) coolant temperature when the fault occurred.
The Demand %( TPI%) when the fault occurred.
ENGINE RPM
0
ENGINE STATE STALL
FPC TOTAL
12.7
FREQ COUNTER
0
↑
↓
←
←
←
←
The engine RPM when the fault occurred.
The engine state when the fault occurred.
The calibrated fueling level when the fault occurred.
The number of times the fault occurred. 0=1 occurrence,
1=2 occurrence
NOTE: Not all parameters are available on all engine models. See
glossary for further descriptions of data labels.
Press F2, 1
Press
To EXIT
Summary of Contents for SmartCraft Systems
Page 9: ...Preface 7 Reference Manual NOTES...
Page 28: ...1 0 Introduction 26 Reference Manual NOTES...
Page 29: ...2 0 Marine Diagnostics 27 Reference Manual OVERVIEW 1 Mercury Marine...
Page 98: ...2 0 Marine Diagnostics 96 Reference Manual NOTES...
Page 107: ...3 0 Glossary of Terms 105 Reference Manual NOTES...